Model: Basic
Wavelength (±20nm): 1310/1550
Dynamic Range(2): 45/43dB
EDZ (m)(3): 0.8
ADZ (m)(3): 4.5
Pulse Width: 10ns, 30ns, 100ns, 300ns, 1µs@850nm; 10ns, 30ns, 100ns, 300ns, 1µs, 2.5µs@1300nm; 5ns, 10ns, 30ns,100ns, 300ns, 1µs,2.5µs, 10µs, 20µs@others
Averaging Time: Quick, 15s, 30s, 1min, 2min, 3min
Distance Measure Accuracy: ±(1m+5×10-5×distance+sampling space)
Attenuation Detect Accuracy: ±0.05dB/dB
Reflection Detect Accuracy: ±4dB
Data Storage: 1000 records
Connectivity: USB
Connector: FC/PC (Interchangeable SC, ST; optional LC)
Power Supply: NiMH Battery / AC Adapter
Battery Life: 8 hrs continuous operation, 20 hrs standby (on one charge); recharging time < 4 hrs
Operating Temperature: -20°C to 50°C
Storage Temperature: -40°C to 70°C
Relative Humidity: 0 to 95% (non-condensing)
Weight: 1kg (2.2 lbs)
Dimensions (H×W×T): 220×110×70mm (8.7×4.3×2.7 inch)
Functional Module Specifications:
Visible Fault Locator Module(5):
Wavelength (±20nm): 650nm
Output Power (dBm): ≥-3
Max Measurement Range: 5 Km
Stabilized Laser Source Module(5):
Wavelength (±20nm): Same as OTDR working wavelength(5)
Output Power (dBm): ≥-7
Optical Power Meter Module(5):
Calibrated Wavelength (nm): 850,1300,1310,1490,1550,1625
Power Range (dBm): -70 to +6 (-60 to +6 @ 850nm)
Detector Type: InGaAs
Display Resolution: 0.01dB
Accuracy: ± 5% ± 0.01nW (±0.5dB@850nm)
MOD Identification: 1K, 2K Hz
PON Power Meter Module(6):
Calibrated Wavelength: 1310nm
Measurement Range (dBm): -40 to +8(Burst mode: -30 to +8)
Spectral Passband (nm): 1310±40
Calibrated Wavelength: 1490nm
Measurement Range (dBm): -40 to +8
Spectral Passband (nm): 1490±10
Calibrated Wavelength: 1550nm
Measurement Range (dBm): -40 to +20
Spectral Passband (nm): 1550±10
Power Uncertainty (dB): ≤ 0.5
Display Resolution (dB): 0.01
Insertion Loss (dB): ≤ 1.5
Threshold: 60 user-definable threshold sets
Data Storage: 1200 records
MCI100 Optical Connector Inspector Module:
Zoom: 250X
Resolution: 0.75μm
Focus: Manual
Adaptor:
Standard:
25-U-M: FC/SC/ST/E2000 UPC male;
125-U-M: LC/MU UPC male;
25-U-F: FC/SC/ST/E2000 UPC female;
LC-U-F: LC UPC female;
Optional:
125-A-M: LC/MU APC male;
25-A-M: FC/SC/ST/E2000 APC male;
SC-A-F: SC APC female;
FC-A-F: FC APC female;
LC-A-F: LC APC female;
* Specifications subject to change without notice
Notes:
(1) Specifications describe the instrument’s warranted performance, measured with typical PC-type connectors. Uncertainties due to the refractive index of fiber are not considered.
(2) The dynamic range is measured at maximum pulse width and averaging time of 3 minutes.
(3) Conditions for dead zone measurement: Reflection event is at 0.6Km, reflection intensity is less than -45dB, event dead zone is
measured with pulse width of 10ns; attenuation dead zone is measured with pulse width of 10ns.
(4) 1625nm can be replaced by 1650nm.
(5) Visible fault locator module, Stabilized laser source module and Optical power meter module is standard on -VPSI models. Stabilized laser source shares palmOTDR optical port and work on the same working wavelength of palmOTDR.
(6) PON power meter module is standard on P11C and P31C.
Order Information
Standard Package Includes:
Instrument, FC/PC connector, NiMH battery, TraceManager software CD, USB Data cable, AC adaptor, Soft carrying case, Warranty card, Certificate of calibration, Quick reference guide.