Input Power: AC 220V ±10% / 50Hz

Input Active Power: 826W

Input Resistance: ≥1MΩ


Resolution: AD 16-bit; DA 16-bit


Voltage:

Per-channel voltage range: 25 mV ~ 5 V

Discharge minimum voltage: 2 V

Accuracy: ±0.05% FS

Stability: ±0.05% FS


Current:

Per-channel current range:

Range 1: 0.5 mA ~ 1 A

Range 2: 1 A ~ 6 A

Range 3: 6 mA ~ 12 A

Accuracy: ±0.05% FS

Constant voltage cut-off current: 0.2 mA / 6 mA / 12 mA

Stability: ±0.05% FS


Power:

Per-channel output power: 60 W

Stability: ±0.1% FS


Time:

Current response time: <1 ms (0–full range)

Step time range: ≤365 × 24 hours per step


Data Recording:

Minimum time interval: 100 ms

Minimum voltage interval: 10 mV

Minimum current interval: 2 mA / 12 mA / 24 mA

Record frequency: 10 Hz


Charge Mode:

Constant current charge (CC)

Constant voltage charge (CV)

Constant current & constant voltage charge (CC-CV)

CPC


Charge cut-off conditions: Voltage, Current, Time, Capacity, -ΔV


Discharge Mode:

CCD, CVD, CCVD, CPD, CRD

Discharge cut-off conditions: Voltage, Current, Time, Capacity


Pulse:

Charge: CCC

Discharge: CCD

Minimum pulse width: 500 ms

Pulse number: up to 32 pulses per step

Automatic switching between charge/discharge per pulse

End condition: Voltage, test time


Cycle:

Loop range: 1–65535 cycles

Max steps per loop: 254

Nested loop: up to 3 layers


Protection:

Software protection, power-down data protection

Offline testing function with parameter limits (voltage/current/time delay)


Noise: <85 dB


Channel Features:

Independent constant current & constant voltage closed-loop structure

Independent channel control

4-wire Kelvin sensing


Database: MySQL

Communication: TCP/IP

Data output: Excel, TXT, graph

Interface: Ethernet

Channels: 8 channels per unit

Operating Temperature: 0°C ~ 40°C

Storage Temperature: -10°C ~ 50°C

Humidity: 30% ~ 80% RH (operation), 30% ~ 90% RH (storage)

Dimensions: 3U2F, 480 × 400 × 130 mm