인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
Detector: 3He proportional counter in polyethylene moderator
Energy range: 0.025 eV – 14 MeV
Indication range of neutron count rate: 0-5•10^4s^-1
Measurement range of ambient neutron radiation dose equivalent rate: 0.1 µSv/h – 10 mSv/h [from Pu-Be source]
Measurement range of ambient neutron radiation dose equivalent: 0.1 µSv – 10 Sv [Pu-Be]
Typical sensitivity to neutron radiation (In dose rate measurement mode): 0.355 cps/(µSv·h^-1 ) [Pu-Be]
Measurement range of neutron flux density: 0.1 – 10^4 neutron•s^-1 •cm^-2
Measurement range of neutron fluence: 1 – 3•10^6 neutron•cm^-2
Typical sensitivity to neutron radiation (In flux density measurement mode): 0,5 cps/(neutron•s^-1 •cm^-2 ) [Pu-Be]
Limit of intrinsic relative measurement error
- Ambient dose equivalent rate : ±35%
- Flux density: ±20%
Protection class: IР64
Interface: RS232
Mean operating life: ≥15 years
Operation temperature range: -40°С to +50°С
Relative air humidity: ≤95% (Air temperature ≤35 С without condensation)
Overall dimensions, weight: Ø90х290 mm / 2 kg