Hanna HI98197 울트라 순수한 물 EC / 비저항 방수 휴대용 측정기 (0.000 - 9.999 μS / cm)

EC Range: 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution: 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy: ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration: automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range: 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution: 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy: ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
TDS Calibration: based on conductivity calibration
Resistivity Range: 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution: 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Resistivity Accuracy: ±1% of reading (±10 Ω or 1 digit, whichever is greater)
Resistivity Calibration: based on conductivity calibration
Salinity Range: % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale - UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution: 0.1%; 0.01
Salinity Accuracy: ±1% of reading
Salinity Calibration: max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges
Temperature Range: -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution: 0.1°C (0.1°F)
Temperature Accuracy: ±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibration: one or two points
Temperature Compensation: noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modes: autorange, autoend, lock and fixed range
Reference Temperature: 15°C, 20°C and 25°C
Temperature Coefficient: 0.00 to 10.00 %/°C
TDS Factor: 0.40 to 1.00
Electrode/Probe: HI763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included)
Log-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles: up to 10
PC Connectivity: opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life: 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off: user selectable: 5, 10, 30, 60 min or can be disabled
Environment: 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions: 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight: 400 g (14.2 oz.)
Ordering Information: HI98197 is supplied with HI763123 conductivity probe, HI605453 stainless steel flow cell, HI7033M 84 μS/cm calibration solution (230 mL), HI7031M 1413 μS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instructions and rugged carrying case.
 

Option: 
- HI6033 84 µS/cm Conductivity Standard in Light Block Bottle (500mL)
- HI7033L 84 µS/cm Conductivity Standard (500mL Bottle)
- HI7031L/C 1413 µS/cm Conductivity Standard (500mL Bottle)
- HI7031L 1413 µS/cm Conductivity Standard (500mL Bottle)
- HI70031P 1413 µS/cm Conductivity Standard (25 x 20mL)