Monitor Console Temperature Range: +15° to +45° C
Analog Outputs (user selectable): ±10 V, 0 - 5V (2.5V, ±2.5V full scale);
<10 Ω impedance; or simultaneous 4-20mA (optional)
RS232/485 Control: Channel status, channel disable / enable, group control
Accuracy: ±3% of full scale at analog outputs
±3% of full scale, ±2% counts
+0.3 counts/0C at front panel meters
Displays: Four 3½-digit LED’s, 0.6”
(one per input channel)
Power Requirements: 90-260 VAC, 47-60 Hz; 13 Watts max.
4 - 20 mA Option
Power Requirements: Internal power supply 11V min
External power supply 24 V max
Alarm Relays: Per channel fail safe, NC (Form B)
System O.K., Channel O.K., Warning, Alarm
Contact Ratings: DC: 1A, 30V
AC: 0.5A, 125V
Connector Styles: RS485 - DB9
Probe - DB9
Analog Out - BNC
Test Connector - Screw Terminals
4-20 mA option - Screw Terminals
Dimensions: 1¾ x 19 x 11 inches
(4.45x 48.26 x 27.9 cm)
Mounts in a standard 19” rack
Weight: approx. 9 lbs
Enclosure (optional)
Capacity: Two Monitor Consoles
Dimensions: (11.4 x 50.8 x 35.6 cm)
Certifcations: CE Mark compliant
Accessories Manual on CD, 110V Line Cord, 220V Line
Included: Cord, DB9 M/F Straight-Thru Cable, USB
A-Male/B-Male Cable, Mounting
Hardware. 2 - 2 Position & 4 - 6
Position plugs
1036 E(H) & F(H) Sensors*
Standard Range: ± 10kV/inch
Optional: ± 1kV/cm (100kV/m)
± 10kV/cm (1MV/m)
± 20kV/cm (2MV/m)
± 1kV/inch
Mua phụ kiện
1036E-6 Standard Industrial Sensor:
1036F-6 Standard General Purpose Sensor:
1036/12 Extension Cable for Model 1036 Sensor (Optional lengths available, consult factory):
96102 Calibration Fixture for Model 1036 Sensors
177ENC Rack Enclosure for Model 177
Download Data Sheet ›
Download Manual ›
Download Front Panel Program Tree › | |
Download Modbus Commands › | |
Download Application Note APNE-0014 › |
|
Download Application Note APNE-0015 › |
|
Download Application Note APNE-0016 › |
Electrostatic Fieldmeter - Static Monitor - model 177A |
|
Multi-point Fieldmeter and Alarm System. Detect static buildup before it becomes a problem. Avoid process interruptions, product loss, electrical shocks, fires, and explosions.
The model 177A is the only intrinsically-safe, multiple-channel fieldmeter system available for long-term, unattended monitoring of static levels at critical points within industrial processes. It cost-effectively monitors up to four locations to determine if static control systems are operating effectively, and it warns when static levels exceed safe operating limits, above which material misbehavior, shocks to personnel, explosions, or fires might occur. Several measurement ranges are available. Tailor sensitivity, range, and alarm thresholds to your needs.
|