For full functionality of this site it is necessary to enable JavaScript.

PCE 830-2-ICA 3상 전력 분석기

Specification

Measurement values: Measurement ranges / resolution / accuracy

PCE-830 + PCE-6801 

Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1):

5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W 

1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W 

10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W 

100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW 

1,000 kW to 9,999 kW / 1 kW / ±1% ±8 kW

PCE-830 + PCE-6802

Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1):

5.0 W to 999.9 W / 0.1 W / ±1% ±0.8 W

1.000 kW to 9.999 kW / 0.001 kW / ±1% ±8 W

10.00 kW to 99.99 kW / 0.01 kW / ±1% ±80 W

100.0 kW to 999.9 kW / 0.1 kW / ±1% ±0.8 kW

1000 kW to 9999 kW / 1 kW / ±1% ±8 kW

0.000 MW to 9.999 MW / 0.001 MW / ±1% ±80 kW

PCE-830 + PCE-3007

Watts AC (50 Hz or 60 Hz, PF 0.5 up to 1):

10.0 W to 999.9 W / 0.1 W / ±1% of measurement range 

1.000 kW to 9.999 kW / 0.001 kW / ±1% of measurement range 

10.00 kW to 99.99 kW / 0.01 kW / ±1% of measurement range 

100.0 kW to 999.9 kW / 0.1 kW / ±1% of measurement range 

1,000 kW to 9,999 kW / 1 kW / ±1% of measurement range

PCE-830 + PCE-6801 

Current AC (50 Hz or 60 Hz, auto range select, TRMS):

0.04 A to 1 A / 0.001 A / ±0.5% ±0.05 A 

0.4 A to 10.0 A / 0.01 A / ±0.5% ±0.05 A 

4 A to 100.0 A / 0.1 A / ±1.0% ±0.5 A

PCE-830 + PCE-6802

Current AC (50 Hz or 60 Hz, auto range select, TRMS):

10.00 A / 0.01 A /

4 A to 100.0 A / 0.01 A / ±0.5% ±0.5 A

40 A to 1000.0 A / 0.1 A / ±0.5% ±5 A

PCE-830 + PCE-3007 

Current AC (50 Hz or 60 Hz, auto range select, TRMS):

0 to 300 A / 0.1 A / ±1.0% of measurement range 

300.0 A to 999.9 A / 0.1 A / ±1.0% of measurement range 

1,000 A to 3,000 A / 1 A / ±1.0% of measurement range

Voltage AC (50 Hz or 60 Hz, TRMS):

20.0 V ... 500.0 V / 0.1 V / ±0.5 % ±5 digits 

(grounded) 

20.0 V ... 600.0 V / 0.1 V / ±0.5 % ±5 digits 

(phase to phase)

Harmonic distortionof AC voltage:

1º to 20º / 0.1% / ±1.0% 

21º to 49º / 0.1% / 4% of reading ±2.0% 

50º to 99º / 0.1% / 6% of reading ±2.0%

PCE-830 + PCE-6801 

Harmonics of AC current in %:

1º to 20º / 0.1% / ±0.2% of reading ±1.0% 

11º to 20º / 0.1% / ±2% of reading ±1.0% 

21º to 50º (A)/ 0.1% / ±5% of reading ±1.0% 

21º to 50º (mA)/ 0.1% / ±10% of reading ±1.0% 

51º to 99º / 0.1% / ±35% of reading ±1.0%

PCE-830 + PCE-6802: 1º to 10º / 0.1% / ±2%

Harmonics of AC current in %:

21º to 49º / 0.1% / 4% of reading ±2.0%

50º to 99º / 0.1% / 6% of reading ±2.0%

PCE-830 + PCE-3007

Harmonics of AC current in %:

1º to 10º / 0.1% / ±2% 

21º to 49º / 0.1% / ±6% 

50º to 99º / 0.1% / ±10%

PCE-830 + PCE-6801 / PCE-830 + PCE-6802

Power Factor (PF): 0.00 to 1.00 / 0.01 / ±0.04

PCE-830 + PCE-3007 

Power Factor (PF): 0.000 to 1,000 / 0.001 / ±0.04

PCE-830 + PCE-6801 / PCE-830 + PCE-6802

Phase angle (Phi): -180° to 180° / 0.1° / ±1°

PCE-830 + PCE-3007 

Phase angle (Phi): 0° to 180° / 0.1° / ±2°

PCE-830 + PCE-6801: 0.0 to 20.0% / 0.1% / ±1% 

Total harmonic distortion:

20.0% to 100% / 0.1% / ±3% of reading ±5% 

100% to 999.9% / 0.1% / ±10% of reading ±10%

PCE-830 + PCE-6802 : 0.0 to 20.0% / 0.1% / ±2%

Total harmonic distortion:

20.0% to 100% / 0.1% / ±6% of reading ±1%

100% to 999.9% / 0.1% / ±10% of reading ±1%

PCE-830 + PCE-3007: 0.0 to 20.0% / 0.1% / ±2%  

Total harmonic distortion:

20.0% to 100% / 0.1% / ±6% of reading ±1% 

100% to 999.9% / 0.1% / ±10% of reading ±1%

Maximum measurement of AC voltage and current:

50 Hz / 19 µS / ±5% ±30 digits 

60 Hz / 16 µS / ±5% ±30 digits

Peak value measurement of AC voltage and current: 1.00 to 99.99 / 0.01 / ±5% ±30 digits

Frequency range in automatic mode: 45 Hz to 65 Hz / 0.1 H z / 0.1 Hz

Memory: 512 kB for a maximum 52,420 readings taken by 1 phase / 2 conductors

Port: USB

Software and cable: included, for Windows 2000, XP, ME

Display :backlit LCD with dot matrix

Power: 8 AA batteries (Mignon)

Dimensions:

257 mm x 155 mm x 57 mm

10.1 in x 6.10 in x 2.24 in

Weight: 1.16 kg / 2.56 lbs

Operating conditions:

max. 85% relative humidity

-10º C to 50º C / 14º F to 122º F

Type of protection / standards: IEC 61010, 600 V/CAT III


Delivery contents

1 x PCE-830-2 Power Analyzer 

3 x Amp clamps - Depending on the set ordered (PCE-6801, PCE-6802 or PCE-3007)

4 x Alligator clips

4 x Safety test lines (3m long)

8 x Batteries

1 x Mains adaptor

1 x Carrying case

1 x USB cablem software

1 x User's manual

1 x ISO Calibration Certificate

Details

Manual