For full functionality of this site it is necessary to enable JavaScript.

PCE TG 300-ICA 두께 측정기 (0.65~600 mm; 2.5~60 mm; ISO Calibration Cert.)

Measuring range:

PE: pulse-echo mode 0.65 ... 600 mm (steel)

EE: echo-echo mode 2.50 ... 60 mm

Accuracy: ± 0.04 mm H [mm] (<10 mm); ± 0.4% H [mm] (> 10 mm)

H refers to the material thickness of the workpiece

Resolution: 0.1 mm / 0.01 mm / 0.001 mm (adjustable)

Measurable materials: Metals, Plastics, Ceramics, Epoxy resin, Glass and all homogeneous materials

Working modes:Pulse echo mode (fault and blower detection); Echo-Echo mode (hiding layer thicknesses, eg paints)

Calibration: Sound velocity calibration, Zeroing, Two-point calibration

View mode: Normal mode, Scan mode, Difference mode

Units: mm / inch

Data transfer: Print via Bluetooth / USB 2.0

Storage: Non-volatile memory with 100 data groups with 100 data sets each

Operating time: Continuous operation 100 h

Automatic stand-by mode (adjustable)

Automatic switch-off mode (adjustable)  

Power supply: 4 x AA battery 1.5V

Display: 320 x 240 pixels TFT LCD color display with brightness adjustment

Operating conditions: 0 ... 50°C / 32 ... 122°F, ≤ 80% RH not condensing

Storage conditions: -20 ... 70°C / -4 ... 158°F, ≤ 80% rh non-condensing

Dimensions: 185 x 97 x 40 mm / 7.3 x 3.8 x 1.6 in

Weight: 375 g / < 1 lb

- Specification of the available sensors for wall thickness gauge PCE-TG 300:  

NO2  

Frequency: 2.5 MHz

Diameter: 14 mm

Measuring range: 3 ... 40 mm (steel); 3 ... 300 mm (steel)

Minimum diameter of pipes : Not suitable for curved materials

Description: For damping / scattering materials (plastics, cast iron)

   

NO5  

Frequency: 5 MHz

Diameter: 10 mm

Measuring range: 1 ... 600 mm (steel)

Minimum diameter of pipes: 20 x 3 mm

Description: Normal measurement

   

NO5 / 90°  

Frequency: 5 MHz

Diameter: 10

Measuring range: 1 ... 600 mm (steel)

Minimum diameter of pipes: 20 x 3 mm

Description: Normal measurement

   

NO7  

Frequency: 7 MHz

Diameter: 6 mm

Measuring range: 0.65 ... 200 mm (steel)

Minimum diameter of pipes: 15 x 2 mm

Description: Or thin-walled or heavily curved pipes

   

HT5  

Frequency: 5 MHz

Diameter: 12 mm

Measuring range: 1 ... 600 mm (steel)

Minimum diameter of pipes: 30 mm

Description: For high temperatures (max 300°C / 572°F)

   

P5EE  

Frequency: 5 MHz

Diameter: 10 mm

Measuring range: PE: 2 ... 600 mm, EE: 2.5 ... 100 mm

Minimum diameter of pipes: 20 x 3 mm

Description: Normal measurement and EE test

Delivery Scope:

1 x Thickness meter PCE-TG 300-ICA

1 x Sensor P5EE

1 x 100 ml coupling gel

1 x Transport case

4 x AA batteries

1 x User manual

1 x ISO Calibration Certificate

Details

Datasheet


Manual

  • 품질 보증
  • 공인 보증
  • 집으로 배달
  • 간단하게 거래하기

할인과 정보를 받기 위해 등록하기