Pintek DP-50 차동 프로브 (6.5KVp-p / 50MHz)
생산업체: PINTEK Model: DP-50 - 견적요구
- 연락처
4 RANGE ATTENUATOR |
|
6500V HIGH VOLTAGE INPUT. | |
<6.5v low="" batt="" indicate="" font=""> | |
<5.5v auto="" power="" off="" font=""> | |
SEPARATING DESIGN, CONVENIENT, DURABLE | |
MEET IEC1010, UL3111, TUV GS, CAT III 6500V |
Differential Voltage DC + pk AC: 6500V
Bandwidth ( 50 Ω load -3dB ): 50MHz( x 100 25MHz)
Common Mode Voltage DC + pk AC: 6500V
Common Mode Voltage RMS CAT II: 6500V
Common Mode Voltage RMS CAT IIIl: 6500V
Attenuation ( Switchable ):X 100, X 200, X 500, X 1000
Input R ( Each input ): 27MΩ±1%
Input C ( Each input ): 2.5 PF ± 2% 2
Maximum Operation Voltage( DC + pk AC )
≦ ± 650V at X 100
≦ ± 1300V at X 200
≦ ± 3250V at X 500
≦ ± 6500V at X 1000
Common Mode Rejection Ration( C M R R )
60 Hz : > 10,000 : 1
100 Hz : > 1,000 : 1
1 MHz : > 300 : 1
Noise ( Into 50Ω load ): ≦ 2 m Vrms
Input Impedance ( between input): 54 MΩ // 1.25 PF >
Accuracy ( at 20 ~ 30℃ 70% RH after 20 minutes ): ≦ ± 2 %
Maximum Output Voltage: ≦ ± 6.5 V
POWER SOURCE: External 6V ~ 9V DC
WARNING
- Do not use DP-50/100 above 6500V ( DC + peak AC ) between ground and the input or 6500V ( DC + peak AC ) between the input lead.
- Do not operate DP-50/100 in wet or damp condition.
- Do not operate DP-50/100 in an explosive atmosphere
- Do not immerse DP-50/100 in liquids.
- Do not operate DP-50/100 without covers.
- Please change the battery when the " LOW BATT"?LED is lighted. At this time DP-5/100 can operate but not guaranteed the accuracy.
FEATURES
- Do not use DP-50/100 above 6500V ( DC + peak AC ) between ground and the input or 6500V ( DC + peak AC ) between the input lead.
- The DP-50/100 converts the high voltage differencial input signal to a low voltage ground refereced signal for display on any Oscilloscope.
- The output BNC of DP-50/100 is calibrated to drive a high impedane ( 1 MΩ ) load.
INSTRUCTION FOR USE
- Connect the output BNC of DP-50/100 to the input BNC of the Oscilloscope by the accessory BNC cable.
- Adjust the vertical offset of the Oscilloscope if necessary.
- Set the select proper range of the DP-50/100 and the V / DIV of the Oscilloscope according to the scale conversion chart.NOTE: If the voltage of the input signal exceeeds the linear range of the setting range. The signal output of the DP-50/100 would not accurately, the wave form display will be cut off.
- Scale conversion chart: The effective V / DIV is the attenuation factor of X 100 ~ X 1000 multiplied by the scale factor of the Oscilloscope. It will be twice when the 50Ω load was used. For example, with the range set at X 200, and the scope set to 0.5V / DIV, the effective V / DIV equals 200 X 0.5 or 100V, when the 50Ω load was used, it becomes 200V, the power consumption will increase too.