Máy hiện sóng (phân tích Bus dữ liệu) LeCroy VBA64Xi-A (600Ghz, 5GS/s, 4CH)
Hãng sản xuất: LECROY Model: VBA64Xi-A - Liên hệ
Tham khảo dịch vụ Hiệu chuẩn-Kiểm định và Sửa chữa
Gọi để có giá tốt
TP. Hà Nội: (024) 35.381.269
TP. Đà Nẵng: (023) 63.747.711
TP. Bắc Ninh: (0222) 730.39.68
TP. Hải Phòng: (0225) 730.03.89
TP. HCM: (028) 38.119.636
Đồng Nai: 0345.689.536
Analog Bandwidth:600 GHz
Single-Shot Sample Rate/Ch:5GS/s
Input Channels:4
Color 10.4" flat-panel TFT-LCD with high resolution touch screen
The Vehicle Bus Analyzer decodes CAN serial data into Symbolic (application layer ) text directly on the oscilloscope display. For the first time, an engineer has both the full range of CAN protocol stack information—symbolic, hex, and electrical signal—and the ability to view additional in-circuit electrical signals (sensors and actuators, voltage levels, transients, etc.) that influence the CAN bus. In addition, up to four different CAN buses can be decoded at one time.Standard and specialized oscilloscope tools can be used to validate and debug designs.
- CAN symbolic (Application Layer) decode of up to 4 CAN buses
- CAN triggering with setup in symbolic format
- CAN digital date extraction with symbolic format setup and plot data as an analog signal
- CAN automated timing measurements
- Compatible with CAN DBC database format
- Includes CANbus TDM, FlexRay TDP, and LINbus TD solutions
- FlexRay, Trigger, Decode, and Physical Layer testing (version 2.1)
- LIN Trigger and Decode supported for 1.3, 2.x, J2602 versions
- FlexRay eye diagram mask testing with error location
- FlexRay physical layer measurement para meters for propagation delay, asymmetric delay, truncation and jitter
- Capture thousands (seconds) of CAN, FlexRay and LINbus messages with up to 25 Mpts of memory
Direct symbolic decoding and triggering allows fast and intuitive understanding of events.Simply load your existing DBC database file into the oscilloscope (no re-entry of data is required); capture CAN message traffic; and all electrical (signal), protocol (hex), and symbolic (application) layer information is quickly displayed on the oscilloscope screen. Use standard oscilloscope and specialized Vehicle Bus Analyzer tools to find rare events, automatically measure and statistically analyze event timing, and graph/plot information, including extracted CAN message data.
The VBA concentrates all your information in one place. Timing measurements across gateways are now possible. Under standing is fast, intuitive, and in a familiar format. Complete, time-correlated understanding of all ECU or circuit behaviors is simple. Time-consuming workarounds are a thing of the past.
The VBA can make many measurements not possible with other instruments. Aside from timing measurements, the VBA can also extract CAN digital data from a CAN message stream, graphically plot that data as an analog signal on the oscilloscope display, and compare it to other electrical signals. Here, information on the steering angle and steering angle rate of change is extracted from the CAN message acquisition, rescaled to decimal values, and plotted as a time-correlated "Track" on the VBA display.
- Symbolic (application layer) decode of up to 4 separate CAN bus
- Symbolic CAN trigger setup
- Hexadecimal decode and trigger setup for CAN, FlexRay and LINbus.
- Binary trigger setup
- Automated timing measurements, including capability to measure timing across gateways:
- CAN message to Analog signal
- Analog signal to CAN message
- CAN message to CAN message
- Bus Load % measurements (up to 2 billion events)
- CAN digital data extraction and display in analog form in scaled decimal values
- CAN message bit rate calculation
- Statistical calculations of many measurements
- Histogram (graphical) display of statistical data, including timing measurements
- Trend and Track plots of extracted CAN data
- Persistence trace, mean, and sigma functionality
- Complete set of Jitter and Timing (@level) parameters
- Supports for 2.5, 5, and 10 Mb/s FlexRay signals
- Physical layer measurement parameters for propagation delay, asymmetric delay, truncation and jitter for FlexRay
OPTION
Serial Data Compliance |
QPHY-ENET QualiPHY Enabled Ethernet 10/100/1000BT Compliance Software Option |
QPHY-USB QualiPHY Enabled USB 2.0 Compliance Software Option |
ENET-2ADA-BNCSMA Adapter Set- 2 BNC/M to SMA/F |
ENET-2CAB-SMA018 Cable Set- 2 SMA-SMA 18 inches |
ENET-2CAB-SMA036 Cable Set- 2 SMA-SMA 36 inches |
ET-PMT Electrical Telecom Pulse Mask Software; |
WRXi-SDM Serial Data Mask Software Package for WaveRunner Xi Series |
Serial Trigger and Decode |
WRXi-USB2-HSICbus D USB 2.0 HSIC Decode Option |
CANbus TD CANbus TD Trigger and Decode Option |
CANbus TDM CAN Bus Trigger, Decode, and Measure/Graph option |
CANbus TD 5LIC CAN Bus Trigger and Decoding Package with License to work on 5 oscilloscopes |
WRXi-NRZbus D NRZ Bus Decode Option for WaveRunner Xi |
WRXi-Manchesterbus D Manchester Bus Decode Option for WaveRunner Xi |
WRXi-ENETbus D ENET Bus Decode Option for WaveRunner Xi |
CANbus TDM-5LIC CAN Bus Trigger, Decode, and Measure/Graph option with 1 Hardware Kit and 5 SW Licenses |
TC1041-OPTO CAN 1041 Opto-isolated High-speed Trigger Coupler |
TC1050-OPTO CAN 1050 Opto-isolated High-speed Trigger Coupler |
TC1054-OPTO CAN 1054 Opto-isolated Low-speed Trigger Coupler |
TC251-OPTO CAN 251 Opto-isolated High-speed Trigger Coupler (one is included with CANbus TD) |
TC10011-OPTO CAN B10011S Opto-isolated Truck and Bus Trigger Coupler |
WRXi-1553 TD MIL-STD-1553 Trigger and decode option for WaveRunner Xi |
WRXi-ARINC429bus DSymbolic ARINC 429 Bus Symbolic Decode option for WaveRunner Xi/Xi-A |
WRXi-AudioBus TD AudioBus trigger and decode for WaveRunner Xi |
WRXi-AudioBus TDG AudioBus trigger, decode, and graph for WaveRunner Xi |
WRXi-DigRF3Gbus D DigRF 3G Bus Decode option for WaveRunner Xi/Xi-A |
WRXi-DPHYbus D D-PHY Bus Decode option for WaveRuner Xi/Xi-A |
WRXI-I2CBUS TD I2C Bus Trigger & Decode Option for WaveRunner Xi Oscilloscopes |
WRXi-PROTObus MAG Serial Debug Toolkit - Measure Analyze Graph for WaveRunner Xi/Xi-ACompatible with I2C, SPI, UART, CAN, LIN, FLX, D-PHY, DigRF 3G, DigRF v4, ARINC 429, MIL-STD-1553 |
WRXi-ProtoSync Decode Annotation and Protocol Analyzer Software Synchronization Option for WaveRunner Xi/Xi-ACompatible with USB2bus D, SATAbus D, SASbus D, FCbus D |
WRXi-SATAbus D SATA Decode option for WaveRunner Xi/Xi-ASupports SATA Gen 1, 2, and 3. |
WRXI-SPIBUS TD SPI Bus Trigger & Decode Option for WaveRunner Xi Oscilloscopes |
WRXi-UART-RS232BUS TD UART and RS232 Bus Trigger and Decode Option for WaveRunner Xi Oscilloscopes |
WRXi-USB2bus D USB 2.0 Bus Decode option for WaveRunner Xi/Xi-A |
WRXI-SENTbus D SENT Bus Decode Option for WaveRunner Xi |
Jitter Analysis Software |
WRXi-JTA2 Jitter and Timing Analysis Software Package for WaveRunner Xi Series |
Miscellaneous |
WRXi-SOFTCASE WRXi Soft Carrying Case |
WRXi-HARDCASE WRXi Hard Carrying Case |
WRXi-KYBD WRXi Keyboard Accessory |
WRXi-RACK WRXi Rack Mount Accessory Kit |
WRXi-MS-CLAMP WRXi Clamp Mounting Stand |
Other Software Options |
WRXi-SPECTRUM Spectrum Analyzer and Advanced FFT Option for WaveRunner Xi Series |
WRXi-EMC EMC Pulse Parameter Package |
WRXi-STAT Histogram and Statistical Analysis Pkg. |
WRXi-XMATH Advanced Math Software Package for WaveRunner Xi Series |
WRXi-XDEV Advanced Customization Software Package for WaveRunner Xi Series |
WRXi-XMAP WRXi Master Analysis Package (XMATH+XDEV+JTA2) |
WRXi-XWAV WRXi Intermediate Math Package |
WRXi-XVAP Value Analysis Software Package (includes XWAV and JTA2) for WaveRunner Xi Series |
WRXi-XWEB Processing Web Editor Software Package for Functions and Parameters for WaveRunner Xi Series |
Data Storage Software |
WRXi-AORM Advanced Options Record Measurement Package |
WRXi-DDM2 Disk Drive Measurement Software Package for WaveRunner Xi Series |
Remote Control/Network Options |
USB2-GPIB External USB 2.0 to GPIB IEEE 488.2 adapter |
Power Analysis Software |
WRXi-PWR Power Analysis Option for WR Xi |
Digital Filtering Software |
WRXi-DFP2 Digital Filter Software Package for WaveRunner Xi Series |
Mixed Signal Solutions |
MS-500 500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed Signal Oscilloscope Option |
MS-500-36 250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s,50 Mpts/ch Interleaved) Mixed Signal Option |
MS-250 250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal Oscilloscope Option |
Mixed Signal Accessories |
PK400-1 Large Gripper Probe Set for 0.10 inch (2.54mm) pin pitch. Includes 10 probes with color coded leads |
PK400-2 Medium Gripper Probe Set for 0.04 inch (1.0mm) pin pitch. Includes 10 probes with color coded leads |
PK400-3 Small Gripper Probe Set for 0.008 inch (0.2 mm) pin pitch. Includes 10 probes with color coded leads |
MSO-MICTOR 36 Channel Mictor Connector for MS Series (Includes 1 MSO-MICTOR-SHROUD) |
MSO-3M 18 Pin 3M Interface cable MSO-3M (Mates with 3M part number 2520-6002) |
MSO-DLS-36 16" Digital Lead Set, D18-D35 |
MSO-MICTOR-SHROUD Shroud for MSO-MICTOR connector, Kit of 3 |
Serial Data Test Fixtures |
TF-ENET-B 10/100/1000BaseT Ethernet Test Fixture |
TF-USB-B USB 2.0 Compliance Test Fixture |
- Cam kết chất lượng
- Bảo hành chính hãng
- Giao hàng tận nơi
- Đơn giản hóa giao dịch