| CATHODE RAY TUBE |
Accuracy |
6 inch diagonal, rectangular screen with internal graticule 8 x 10 DIV ( 1 DIV = 1 cm ), P31 phosphor. 14 kV accel voltage. |
+ / - 3%. |
| Sweep Magnification |
| VERTICAL DEFLECTION |
10X, +/- 10% extend sweep speed up to 2nS/DIV. |
| Bandwidth |
Delay Time Position |
| DC-100 MHz ( -3db ) |
Variable control to locate desirable waveform for extending. |
| Sensitivity |
TRIGGERING |
1 mV / DIV - 1 V / DIV ( 25 MHz -3db ). x 5 gain selected. 5 mV / DIV - 5 V / DIV |
Trigger Coupling |
| Attenuator |
AC,TV-V(DC), TV-H, LINE. |
| 1-2-5 sequence. 10 step with variable control. |
Trigger Source |
| Input Impedance |
CH 1, CH2, ALT, LINE, EXT. |
| 1MΩ ± 2% // 25 pF± 10 pF |
Slope |
| Max. Input Voltage |
+ / - |
| 400 V ( DC + AC peak ). |
TRIGGER SENSITIVITY |
Rise Time 5mV/DIV - 5V/DIV : 3.5 nS 1mV/DIV : 14 nS Over Shoot Less than + / - 5 % Operation Mode |
| COUPLING |
BANDWIDTH(Hz) |
INT(DIV) |
EXT(V) |
TV - V TV - H AUTO NORM |
DC - 1 kHz 1 k - 100 k 100 - 100 M 100 - 100 M |
1.0 1.0 2.0 2.0 |
0.1 0.1 0.2 0.2 |
|
CH 1, CH 2, DUAL (ALT, CHOP) Algebraic Addition |
CH 2 OUTPUT Ouptut level |
CH 1 + CH 2, CH 1 - CH 2 Inverter CH 2 only. |
100 mV/DIV (no load). 50 mV/DIV (with 50Ω load). Bandwidth |
| HOIZONTAL DEFLECTION |
20 Hz-20 MHz ( -3 db ). |
| X-Y Mode switch selectable using X-Y switch |
Calibrator |
| CH 1 : X axis. |
Square wave 1 KHz ± 10 %, 0.5 Vp-p ± 3 % |
| CH 2 : Y axis. |
Z-Modulation |
Accuracy Y - Axis + / - 3 % |
Positive TTL signal, low level blank intensity at any intensity, high level unblank any intensity. |
| X - Axis + / - 6 % |
Trace Rotation |
| Bandwidth |
Adjustable on front panel. |
| DC - 1 MHz ( -3db ). |
Power Source |
| X-Y Phase Difference |
115, 230VAC ± 10%, 50/60 Hz. |
| Approximately 3° at 50 kHz. |
Power Consumption |
| SWEEP SYSTEM |
Apporx. 60 Watts. |
| Sweep Display Mode |
Dimensions |
| Main, Mix, Delay. |
324 (W) x 398 (D) x 132 (H) mm. |
| Hold Off Time |
Net Weight |
| 5:1 continuously variable. ( 0.1µS / DIV ) |
Approx. 8.5 kg. |
| MAIN SWEEP |
Rated Range of Use |
| Sweep Speed |
10℃ - 35℃, 10-80% R.H. |
| 20 nS / DIV - 0.5S / DIV in 1-2-5 sequence 23 steps. |
Limits of Operation |
| Accuracy |
0℃ - 50℃, 10-80% R.H. |
| + / -3 %. |
Storage Environment |
| Variable Time Control |
- 30℃ - 70℃, 10-90% R.H. |
| 5:1, uncalibrated, continuously variable between steps. |
C E STANDARD : |
| Sweep Magnification |
E.M.C. Regulations-1992 ( e.c. Directive 89/336/EEC ) |
|
10X, +/- 10% extend sweep speed up to 2 nS / DIV.
|
EN 50081-1 Emissions. EN 50082-1 limmunity. |
| DELAY SWEEP |
|
| Sweep Speed |
|
| 20 nS / DIV - 0.5S / DIV in 1-2-5 sequence 23 steps. |
|