emin

Máy phân tích phổ thời gian thực Tektronix RSA6120B (9 kHz - 20 GHz)

  • Cam kết chất lượng
  • Bảo hành chính hãng
  • Giao hàng tận nơi
  • Đơn giản hóa giao dịch

Hãng sản xuất: Tektronix
Model: RSA6120B

 

Datasheet

Specifications

All specifications apply to all models unless noted otherwise.

Model overview

For optional displays and measurements, see the individual options sections

 
DPX®-based measurements on real-time data

DPX Spectrum display (live RF color-graded spectrum)

DPX Spectrogram (Live spectrograms)

DPX amplitude vs. time

DPX frequency vs. time

DPX phase vs. time

Displays and Measurements from acquisition data

Spectrum (amplitude vs linear or log frequency)

Spectrogram (amplitude vs. frequency over time of acquisition data)

Spurious (amplitude vs linear or log frequency)

Amplitude vs. time

Frequency vs. time

Phase vs. time

Amplitude modulation vs. time

Frequency modulation vs. time

Phase modulation vs. time

RF IQ vs. time

Time overview

CCDF

Peak-to-Average ratio

Frequency offset measurement
Signal analysis can be performed either at center frequency or the assigned measurement frequency up to the limits of the instrument acquisition and measurement bandwidths
Acquisition replay
Replay entire contents of acquisition memory or subset of acquisitions and frames. history can collect up to 64,000 acquisitions (each containing one or more frames) or 1 GB of sample data, including DPX spectrogram data, whichever limit is reached first
Frequency characteristics
Center frequency setting resolution
0.1 Hz
Frequency marker readout accuracy

±(RE × MF + 0.001 × Span + 2) Hz

(RE = Reference frequency error)

(MF = Marker frequency (Hz))

Span accuracy
±0.3% (auto mode)
Reference frequency
Initial accuracy at cal
1 × 10  -7 (after 10 minute warm-up)
Aging per day
1 × 10  -9 (after 30 days of operation)
Aging per year
5 × 10  -8 (first year of operation)
Aging per 10 years
3 × 10  -7 (after 10 years of operation)
Temperature drift
2 × 10  -8 (0 to 50 °C)
Cumulative error (temperature + aging)
4 × 10  -7 (within 10 years after calibration, typical)
Reference output level
>0 dBm (internal reference selected)
Reference output level (loopthrough)
0 dB nominal gain from Ext Ref In to Ref Output, +15 dBm max output
External reference input frequencies
1 to 25 MHz (1 MHz steps) + 1.2288 MHz, 4.8 MHz, 19.6608 MHz, 31.07 MHz
External reference input requirements
Frequency accuracy
Within ±3 × 10  -7 of a valid listed input frequency
Spurious
< -80 dBc within 100 kHz offset to avoid on-screen spurious
Input level range
-10 dBm to +6 dBm
Trigger related characteristics
Trigger event source
RF input, Trigger 1 (front panel), Trigger 2 (rear panel), Gated, Line
Trigger setting
Trigger position settable from 1 to 99% of total acquisition length
Trigger combinatorial logic
Trigger 1 AND trigger 2 / gate may be defined as a trigger event
Trigger actions
Save acquisition and/or save picture on trigger
Power level trigger
Level range
0 dB to –100 dB from reference level
Accuracy
For trigger levels >30 dB above noise floor, 10% to 90% of signal level
Level ≥ –50 dB from reference level
±0.5 dB
From < –50 dB to –70 dB from reference level
±1.5 dB
Trigger bandwidth range
At maximum acquisition BW
Standard
4 kHz to 20 MHz + wide open
Opt. 110 
11 kHz to 60 MHz + wide open
Trigger position timing uncertainty
40 MHz acquisition BW, 20 MHz BW
Uncertainty = ±15 ns
110 MHz acquisition BW, 60 MHz BW (Opt 110)
Uncertainty = ±5 ns
Trigger re-arm time, minimum (fast frame on)
10 MHz acquisition BW
≤25 μs
40 MHz acquisition BW
≤10 μs
110 MHz acquisition BW (Opt. 110)
≤5 μs
Frequency mask trigger (Opt. 52)
Mask shape
User defined
Mask point horizontal resolution
<0.12% of span
Level range
0 dB to –80 dB from reference level
Level accuracy 1
0 to –50 dB from reference level
±(Channel response + 1.0 dB)
–50 dB to –70 dB from reference level
±(Channel response + 2.5 dB)

1 For masks >30 dB above noise floor.

Span range

100 Hz to 40 MHz

100 Hz to 110 MHz (Opt. 110)

Minimum signal duration for 100% probability of trigger at 100% amplitude
Events lasting less than minimum event duration specification will result in degraded frequency mask trigger accuracy.
Opt. 110 SPAN = 110 MHz
FMT RBW Minimum even duration (μs)
Std. Opt. 09 
10 MHz 17.3  3.7 
1 MHz 19.5  5.8 
100 KHz 37.6  37.6 
Std. SPAN = 40 MHz
FMT RBW Minimum even duration (μs)
Std. Opt 09 
5 MHz 17.5  3.9 
1 MHz 19.5  5.8 
300 KHz 25.1  11.4 
100 KHz 37.7  30.9 
Trigger position uncertainty
Acquisition bandwidth Opt. 52 (RBW = Auto) Opt. 52 plus Opt. 09 (RBW = Auto)
40 MHz ±12.6 μs ±5.8 μs
110 MHz ±9.8 μs ±3 μs
Advanced triggers
DPX density trigger
Density range
0 to 100% density
Horizontal range

0.25 hz to 40 MHz

0.25 Hz to 110 MHz (Opt. 110)

Runt trigger
Runt definitions
Positive, Negative
Accuracy (for trigger levels >30 dB above noise floor, 10% to 90% of signal level)

±0.5 dB (level ≥ –50 dB from reference level)

±1.5 dB (from < –50 dB to –70 dB from reference level)

Time qualified triggering
Trigger types and source
Time qualification may be applied to: Level, Frequency mask (Opt. 52), DPX density, Runt, Ext. 1, Ext. 2 
Time qualification range

T1: 0 to 10 seconds

T2: 0 to 10 seconds

Time qualification definitions

Shorter than T1

Longer than T1

Longer than t1 AND shorter than T2

Shorter than t1 OR longer than t2

Frequency edge trigger
Range
±(1/2 × (Acq. BW or TDBW if active))
Minimum event duration

25 ns for 40 MHz acquisition BW using no trigger RBW

50 ns for 40 MHz acquisition BW using 20 MHz trigger RBW

9.1 ns for 110 MHz Acq. BW using no RBW

16.7 ns for 110 MHz Acq. BW using 60 MHz trigger RBW

.
Timing uncertainty
Same as power trigger position timing uncertainty
Holdoff trigger
Range
20 ns to 10 seconds
Minimum signal duration

For 100% probability of intercept, full amplitude

110 MHz span
RBW FFT length Spectrums /sec Minimum event duration 100% POI (μs)
Base unit Opt. 09 
10000  1024  292,969  17.3  3.7 
1000  1024  292,969  19.5  5.8 
300  2048  146,484  28.5  14.8 
100  4096  73,242  37.6  37.6 
30  16384  18,311  134.6  134.6 
20  32768  18,311  229.2  229.2 
40 MHz span
RBW FFT length Spectrums /sec Minimum event duration 100% POI (μs)
Base unit Opt. 09 
5000  1024  292,969  17.5  3.9 
1000  1024  292,969  19.4  5.8 
300  1024  146,484  25  11.4 
100  2048  73,242  37.6  30.8 
30  4096  36,621  93.6  93.6 
20  8192  18,311  147.3  147.3 
10  16384  18,311  194.5  194.5 
External trigger 1
Level range
-2.5 V to +2.5 V
Level setting resolution
0.01 V
Trigger position timing uncertainty (50 Ω input impedance)
MHz acquisition BW, 40 MHz span
Uncertainty = ±20 ns
110 MHz acquisition BW, 110 MHz span (Opt. 110)
Uncertainty = ±12 ns
Input impedance
Selectable 50 Ω/5 kΩ impedance (nominal)
External trigger 2
Threshold voltage
Fixed, TTL
Input impedance
10 kΩ (nominal)
Trigger state select
High, Low
Acquisition related
A/D converter
100 MS/s 14 bit (optional 300 MS/s, 14 bit, Opt. 110)
Minimum acquisition length
64 samples
Acquisition length setting resolution
1 sample
Fast frame acquisition mode
>64,000 records can be stored in a single acquisition (for pulse measurements and spectrogram analysis)
Memory depth (time) and minimum time domain resolution
Acquisition BW Sample rate (for I and Q) Record length Record length (Opt. 53) Time resolution
110 MHz (Opt. 110) 150 MS/s 1.79 s 7.15 s 6.6667 ns
60 MHz (Opt. 110) 75 MS/s 3.58 s 14.31 s 13.33 ns
40 MHz 50 MS/s 4.77 s 19.08 s 20 ns
20 MHz 25 MS/s 9.54 s 38.17 s 40 ns
10 MHz 12.5 MS/s 19.08 s 76.35 s 80 ns
5 MHz 6.25 MS/s 38.17 s 152.7 s 160 ns
2 MHz 1 3.125 MS/s 42.9 s 171.8 s 320 ns
1 MHz 1.56 MS/s 85.8 s 343.5 s 640 ns
500 kHz 781 kS/s 171.7 s 687.1 s 1.28 μs
200 kHz 390 kS/s 343.5 s 1374 s 2.56 μs
100 kHz 195 kS/s 687.1 s 2748 s 5.12 μs
50 kHz 97.6 kS/s 1374 s 5497 s 10.24 μs
20 kHz 48.8 kS/s 2748 s 10955 s 20.48 μs
10 kHz 24.4 kS/s 5497 s 21990 s 40.96 μs
5 kHz 12.2 kS/s 10955 s 43980 s 81.92 μs
2 kHz 3.05 kS/s 43980 s 175921 s 328 μs
1 kHz 1.52 kS/s 87960 s 351843 s 655 μs
500 Hz 762 S/s 175921 s 703687 s 1.31 ms
200 Hz 381 S/s 351843 s 1407374 s 2.62 ms
100 Hz 190 S/s 703686 s 2814749 s 5.24 ms

1 In spans ≤2 MHz, higher resolution data is stored, reducing maximum acquisition time.

Bandwidth related
Resolution bandwidth
Resolution bandwidth range (spectrum analysis)

0.1 Hz to 8 MHz

0.1 Hz to 10 MHz (Opt. 110)

Resolution bandwidth shape
Approximately Gaussian, Shape factor 4.1:1 (60:3 dB) ±10%, typical
Resolution bandwidth accuracy
±1% (auto-coupled RBW mode)
Alternative resolution bandwidth types
Kaiser window (RBW), –6 dB mil, CISPR, Blackman-Harris 4B window, Uniform (none) window, Flat-top (CW ampl.) window, Hanning window
Video bandwidth
Video bandwidth range
1 Hz to 10 MHz plus wide open
RBW/VBW maximum
10,000:1 
RBW/VBW minimum
1:1 plus wide open
Resolution
5% of entered value
Accuracy (typical)
±10%
Time domain bandwidth (amplitude vs. time display)
Time domain bandwidth range
At least 1/10 to 1/10,000 of acquisition bandwidth, 1 Hz minimum
Time domain bandwidth shape

≤10 MHz, Approximately Gaussian, Shape factor 4.1:1 (60:3 dB), typical

20 MHz (60 MHz, Opt. 110), Shape factor< 2.5:1 (60:3 dB) typical

Time domain bandwidth accuracy

1 Hz to 10 MHz = 1% (auto-coupled)

20 MHz and 60 MHz = 10%

Minimum settable spectrum analysis RBW vs. span
Frequency span RBW
>10 MHz 100 Hz
>1 MHz to 10 MHz 10 Hz
>5 kHz to 1 MHz 1 Hz
≤5 kHz 0.1 Hz
Spectrum display traces, detector, and functions
Characteristic Description
Traces Three traces + 1 math waveform + 1 trace from spectrogram for spectrum display
Detector Peak, –Peak, Average, ±Peak, Sample, CISPR (Avg, Peak, Quasi-peak, Average of logs)
Trace functions Normal, Average, Max hold, Min hold, Average of logs
Spectrum trace length 801, 2401, 4001, 8001, or 10401 points
Minimum FFT length vs. Trace length (independent of span and RBW)
Trace length (points) Minimum FFT length
801  1024 
2401  4096 
4001  8192 
10401  16384 
Resolution BW range vs. span (DPX®)
Acquisition bandwidth RBW (min) RBW (max)
110 MHz 20 kHz 10 MHz
55 MHz 10 kHz 5 MHz
40 MHz 10 kHz 3 MHz
20 MHz 5 kHz 2 MHz
10 MHz 2 kHz 1 MHz
5 MHz 1 kHz 500 kHz
2 MHz 500 Hz 200 kHz
1 MHz 200 Hz 100 kHz
500 kHz 100 Hz 50 kHz
200 kHz 50 Hz 20 kHz
100 kHz 20 Hz 10 kHz
50 kHz 10 Hz 5 kHz
20 kHz 5 Hz 2 kHz
10 kHz 2 Hz 1 kHz
5 kHz 0.1 Hz 500 Hz
2 kHz 0.1 Hz 200 Hz
1 kHz 0.1 Hz 100 Hz
500 Hz 0.1 Hz 50 Hz
200 Hz 0.1 Hz 20 Hz
100 Hz 0.1 Hz 10 Hz
Minimum RBW, swept spans
10 kHz
DPX® related
DPX® digital phosphor spectrum processing
Spectrum processing rate (RBW = auto, trace length 801)
292,968/s
DPX bitmap resolution
201 × 801 
DPX bitmap color dynamic range
8G (99 dB)
Marker information
Amplitude, frequency, and signal density on the DPX display
Minimum signal duration for 100% probability of detection (Max-hold on)
See table: Minimum signal duration for 100% probability of intercept, full amplitude
Span range (continuous processing)

100 Hz to 40 MHz

(110 MHz with opt. 110)

Span range (swept)
Up to instrument frequency range
Dwell time per step
50 ms to 100 s
Trace processing
Color-graded bitmap, +Peak, –Peak, Average
Trace length
801, 2401, 4001, 10401 
Resolution BW accuracy
7%
DPX® zero-span amplitude, frequency, phase performance (Nominal)
Measurement bandwidth range
100 Hz to maximum acquisition bandwidth of instrument
Time domain bandwidth (TDBW) range
At least 1/10 to 1/10,000 of acquisition bandwidth, 1 Hz minimum
Time domain bandwidth (TDBW) accuracy
±1%
Sweep time range

100 ns (minimum)

1 s (maximum, measurement BW >60 MHz)

2000 s (maximum, measurement BW ≤60 MHz)

Time accuracy
±(0.5 % + reference frequency accuracy)
Zero-span trigger timing uncertainty (power trigger)
+/-(Zero-span sweep time / 400) at trigger point, for S/N ratio ≥40 dB
DPX frequency display range
±100 MHz maximum
DPX phase display range

±200 degrees maximum, phase-wrapped

±500G degrees, phase-unwrapped

DPX® spectrogram performance
Span range
100 Hz to maximum acquisition bandwidth
DPX spectrogram trace detection
+Peak, –Peak, avg (VRMS)
DPX spectrogram trace length
801 to 4001 
DPX spectrogram memory depth

Trace length = 801: 60,000 traces

Trace length = 2401: 20,000 traces

Trace length = 4001: 12,000 traces

Time resolution per line
110 µs to 6400 s, user settable
Maximum recording time vs. line resolution
6.6 seconds (801 points/trace, 110 μs/line) to 4444 days (801 points/trace, 6400 s/line)
Stability
Residual FM
<2 hz="" sub="">p-p in 1 second (95% confidence, typical)
Phase noise sidebands
dBc/Hz at specified center frequency
CF = 1 GHz
Offset Specification Typical
100 Hz –86  –86 
1 kHz –100  –106 
10 kHz –106  –110 
100 kHz –107  –113 
1 MHz –128  –134 
6 MHz –134  –142 
10 MHz –134  –142 
CF = 2 GHz
Offset Specification Typical
100 Hz --- – 80 
1 kHz --- –106 
10 kHz --- –110 
100 kHz --- –111 
1 MHz --- –133 
6 MHz --- –142 
10 MHz --- –142 
CF = 6 GHz
Offset Specification Typical
100 Hz --- – 70 
1 kHz --- –96 
10 kHz

EMIN là Nhà phân phối Tektronix - Keithley chính thức tại Việt Nam

Kể từ tháng 3/2015, EMIN được hãng Tektronix - Mỹ, chỉ định chính thức là Nhà phân phối các sản phẩm và dịch vụ của Tektronix tại thị trường Việt Nam.

Giới thiệu về hãng Tektronix:

Nhà phân phối Tektronix chính thức tại Việt Nam
Website chính thức: www.tektronix.com

Tektronix được thành lập năm 1946 tại Mỹ. Với gần 70 năm kinh nghiệm, được cấp 697 bằng sáng chế sản phẩm và được trao hơn 50 giải thưởng danh giá. Tektronix hiện đang là nhà cung cấp hàng đầu các thiết bị đo đạc phân tích tín hiệu điện tử, với những sáng tạo không ngừng về thiết kế và phát triển công nghệ tiên tiến. 
Vào tháng 9/2010, Tektronix mua lại công ty dụng cụ đo lường Keithley Instrument (trụ sở tại Solon, Ohio, Mỹ) và sớm sát nhập thương hiệu này phát triển song song cùng thương hiệu Tektronix trong cùng một hệ thống.
 
Trụ sở chính của Tektronix đặt tại Beaverton, Oregon với mạng lưới phân phối và dịch vụ khách hàng trên toàn cầu.
Các kỹ sư Tektronix luôn cải tiến các giải pháp cho kiểm tra, đo lường và giám sát để giải quyết những thách thức về thiết kế, nâng cao năng suất và tiết kiệm thời gian.
Hệ thống quản lý chất lượng trên toàn cầu
Dù bạn đang ở nơi đâu, Tektronix cũng có hệ thống quản lý chất lượng cho phép khách hàng để thiết kế, xây dựng, triển khai và quản lý "Next Generation" mạng thông tin toàn cầu và công nghệ internet.
 
"Luôn đáp ứng mong đợi của khách hàng cho chất lượng, giao hàng, chi phí và đổi mới (QDCI). Chúng tôi sẽ liên tục cố gắng để cải thiện trong tất cả các lĩnh vực."

Chất lượng và an toàn

Chất lượng sản phẩm, độ tin cậy và an toàn là yếu tố quan trọng cho các khách hàng của chúng tôi. Sự an toàn và chất lượng sản phẩm được phát triển từ kinh nghiệm gần 70 năm của Tektronix trong thiết kế kỹ thuật, dịch vụ và bảo trì.

EMIN Việt Nam là Nhà phân phối Tektronix - Keithley chính thức tại Việt Nam 

Sản phẩm phân phối: Máy hiện sóng, Máy phát tần số cao, Máy phân tích phổ, Đồng hồ vạn năng, Thiết bị đếm tần, Nguồn 1 chiều...

Xem đầy đủ Thiết bị Tektronix tại: 
https://emin.vn/tektronix-123/ma.html
Thiết bị Keithley tại: 
https://emin.vn/keithley-127/ma.html
___________
EMIN Việt Nam vinh dự nhận được bằng khen của hãng Tektronix tại Hội nghị tri ân khu vực Asean năm 2016, tổ chức ở Thái Lan. 

 

EMIN & Tektronix đồng tổ chức: IoT Workshop 2018 tại Hà Nội và TP HCM 

Chương trình đào tạo về đo lường IoT(Internet of Things), IIoT(Industrial Internet of Things), Industry 4.0 tại Hà Nội và HCM City do EMIN Vietnam và Tektronix đồng tổ chức và tài trợ đã diễn ra vào ngày 6,7,8 Tháng 8 vừa qua.

Thuật ngữ ” Internet of things” (viết tắt là IOT) - "Internet vạn vật" dạo gần đây xuất hiện khá nhiều và thu hút không ít sự quan tâm chú ý của thế giới công nghệ. Sự bùng nổ của IOT trong tương lai hứa hẹn sẽ thay đổi thế giới bằng cách kết nối các thiết bị thành các hệ thống lớn hơn, có khả năng tương tác nhiều hơn được kiểm soát bởi phần mềm và phân tích.

Industrial Internet of things (Viết tắt là IIOT) là ứng dụng của internet of thing trong lĩnh vực công nghiệp. 

Internet vạn vật thực chất là nhúng các thiết bị, phương tiện vận tải (được gọi là "thiết bị kết nối" và "thiết bị thông minh"), phòng ốc và các trang thiết bị khác với các bộ phận điện tử, phần mềm, cảm biến, cơ cấu chấp hành cùng với khả năng kết nối mạng máy tính giúp cho các thiết bị này có thể thu thập, truyền tải, xử lý dữ liệu và vận hành tự động

Tại chương trình đào tạo này, chúng tôi mang đến giải pháp kết nối đồng bộ các thiết bị đo lường hàng đầu về IoT, IIoT, của hãng Tektronix. Đặc biệt, khách tham dự được đào tạo sử dụng thiết bị đo, thực hành trực tiếp trên thiết bị, dưới sự hướng dẫn trực tiếp, "Cầm tay chỉ việc" bởi các chuyên gia hàng đầu đến từ Tektronix (Một trong những công ty hàng đầu về thiết bị đo lường trên thế giới). 
Từ đó có cái nhìn tổng thể hơn về IoT, IIoT đo lường trong IoT và 100% thành thạo hơn trong việc sử dụng các thiết bị đo.

Chuyên gia đến từ Tektronix trực tiếp hướng dẫn khách tham dự

Kỹ thuật viên EMIN hướng dẫn khách tham dự

Chương trình đào tạo diễn ra 3 ngày thu hút khách tham dự. Tuy nhiên để hiệu quả đào tạo tốt nhất, số lượng người tham dự được giới hạn (dưới 18ng/ngày)

Thay đổi vị trí để thực hành

Chương trình đào tạo đo lường trong IoT lần này là nơi để các kỹ sư, các nhà nghiên cứu học hỏi, trau dồi kiến thức, kỹ năng. Bên cạnh đó, đây cũng là cơ hội tốt để trao đổi kinh nghiệm trong công việc, gặp gỡ trò chuyện với các chuyên gia nước ngoài, các kỹ sư, kỹ thuật viện,nhà nghiên cứu đến từ các lĩnh vực điện, điện tử, IT,..v..v

Bàn Tea-break giữa giờ, Khách tham dự giao lưu, trò chuyện

Đến với Workshop, khách tham dự được thực hành trực tiếp, với sự hướng dẫn hỗ trợ tận tình

Nhờ sự tham dự đông đủ, nhiệt tình của Quý vị khách quý. Cả 3 buổi đào tạo đã diễn ra thành công tốt đẹp.
Thay mặt ban tổ chức "Tektronix IoT Workshop 2018" xin gửi lời cảm ơn đến Quý vị đã quan tâm và tình cảm quý mến. Rất mong Quý vị tiếp tục đồng hành và tham dự những sự kiện tiếp theo của EMIN.

 

EMIN & Tektronix: IoT Workshop tại HCM  


Chuyên gia đến từ Tektronix trực tiếp hướng dẫn khách tham dự

Kỹ thuật viên EMIN hướng dẫn khách tham dự

Chương trình đào tạo diễn ra 3 ngày thu hút khách đăng ký tham dự. Tuy nhiên để hiệu quả đào tạo tốt nhất, số lượng người tham dự được giới hạn (dưới 18ng/ngày)


Chương trình đào tạo đo lường trong IoT lần này là nơi để các kỹ sư, các nhà nghiên cứu học hỏi, trau dồi kiến thức, kỹ năng. Bên cạnh đó, đây cũng là cơ hội tốt để trao đổi kinh nghiệm trong công việc, gặp gỡ trò chuyện với các chuyên gia nước ngoài, các kỹ sư, kỹ thuật viện,nhà nghiên cứu đến từ các lĩnh vực điện, điện tử, IT,..v..v

Tea-Break time Giao lưu, trò chuyện 

Trực tiếp vận hành máy, dưới sự hướng dẫn, hỗ trợ đến từ các chuyên gia nước ngoài & đội ngũ kỹ thuật viên EMIN Việt Nam

Đến với Workshop, khách tham dự được thực hành trực tiếp, với sự hướng dẫn hỗ trợ tận tình

Nhờ sự tham dự đông đủ, nhiệt tình của Quý vị khách quý. Cả 3 buổi đào tạo đã diễn ra thành công tốt đẹp.
Thay mặt ban tổ chức "Tektronix IoT Workshop 2018" xin gửi lời cảm ơn đến Quý vị đã quan tâm và tình cảm quý mến. Rất mong Quý vị tiếp tục đồng hành và tham dự những sự kiện tiếp theo của EMIN.
Xin chân thành cảm ơn và hẹn gặp lại tại những sự kiện tiếp theo!

Đăng ký nhận bản tin - cơ hội nhận khuyến mãi