SPECIFICATION
Pipe diameter range: 10 mm to 6,500 mm
Temperature range for sensors: -30 °C to +250 °C (-22 °F to +482 °F), higher temperatures available on request
Lockable and sturdy IP 66 polycarbonate flowmeter enclosure
Selectable three-line LCD display and full keypad
Up to ten input or output slots available
Measurement of two flows simultaneously
PERFORMANCE
Measurement principle: Ultrasonic transit-time difference
Flow velocity range: 0.01 ... 25 m/s
Resolution: 0.25 mm/s
Repeatability: 0.15 % of measured value, ±0.015 m/s
Accuracy:
Volume flow:
±1 ... 3 % of measured value depending on application
±0.5 % of measured value with process calibration
Flow velocity (mean): ±0.5 % of measured value
Turn down ratio: 1/100 (equivalent to 0.25 ... 25 m/s)
Measurement rate: 1 Hz (standard)
Response time: 1 s; 90 m/s (optional)
Damping of displayed value: 0 ... 99 s (selectable by user)
Gaseous and solid content of liquid media: < 10 % of volume
APPLICATIONS
Heating, Ventilation and Air Conditioning (HVAC) measurements
Large pipe measurement with two sensor pairs in ‘X’
configuration
Product recognition and interface detection systems
ATEX measurements with Ex-certified transducers
Effluent and wastewater measurements
Automated process control