For full functionality of this site it is necessary to enable JavaScript.

GOTT GOTT-MSFSS-FTM4 流量传感器系统测试模块

PRODUCT MODULES

MAINS POWER SUPPLY - CODE 452-026

• Input voltage: AC220-240V 

• FCCB 2 Pole 16A 

• RCCB 2 pole 25A

T-JOINT - CODE 624-877

Tubing Size: 1/4 inch

PRESSURE SENSOR - CODE 624-873 

• Mini Pressure Transducer Sender Sensor Stainless Steel For Oil Fuel Air Water (30 Psi) 

• Range: 0 to 30 psi 

• Voltage: DC 5V

WATER FLOW SWITCH - CODE 624-872

• AC240V Contact: NO 

• Water flow: 1.0L/min

WATER FLOW METER - CODE 624-871

• Range: 0-4 l/min

WATER FLOW SENSOR - CODE 624-874

• Power Supply: DC 5V 

• Range: 1-5L/min 

• Working voltage: DC 5V-24V

WATER DIFFERENTIAL PRESSURE SENSOR - CODE 624-875

• Pressure range: 0kPa-100kPa 

• Power supply: ≤2.0mA DC; ≤10V DC

DC POWER SUPPLY - CODE 955-124

• Input voltage: AC220-240V 

• Output Voltage: 

• +24VDC/2A 

• +12VDC/7A 

• +5VDC/7A

WATER TANK - CODE 624-876 

• Diameter: 195mm 

• Height: 500mm

UNDERWATER PUMP - CODE 624-874

• Super Submersible Pump 

• AC220V 50Hz 60W

• Flow rate : 3000 L/H

EXPERIMENT TOPICS

• Study the function of water flow meter. 

• To measure the water flow rate generated by an underwater pump using a water flow meter of changeable area. 

• Study the function of water flow switch 

• To use the water flow switch to detect the water flow 

• Study the function of the water flow sensor. 

• To measure the output signal produced by an underwater pump using the water flow sensor. 

• Study the function of the pressure sensor. 

• To use the pressure sensor to measure the output voltage of different liquid level in the water tank. 

• Study the function of water differential pressure sensor. 

• To measure the output voltage of water differential pressure sensor

*This module is design as a whole unit but only can be conducted together with our Computer controlled based unit GOTT-MSFSS-CCBU

Manuals: 

(1) All manuals are written in English. 

(2) Model Answer 

(3) Teaching Manuals

Details

Datasheet


DESCRIPTION: 

GOTT-MSFSS-FTM4 is designed to show techniques to measure changeable fluids. The module is made up of tanks assembled on a structure. Inside them there is a pumping system that allows to pump the water . The pump enables that a big amount of water from the tank flows. It is possible to change the flow volume by changing the pump power supply voltage using the terminals placed on the front panel. GOTT-MSFSS-FTM4 has been invented as a whole unit but only can be conducted together with our Computer controlled based unit GOTTMSFSS-CCBU.

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会