For full functionality of this site it is necessary to enable JavaScript.

Kestrel 5500 手持式气象仪

SENSORS
SENSORSACCURACYRESOLUTIONSPECIFICATION RANGENOTES
Wind Speed | Air SpeedLarger of 3% of reading, least significant digit or 20 ft/min Speed0.1 m/s 1 ft/min 0.1 km/h 0.1 mph 0.1 knots 1 B* 0.1 F/S*0.6 to 40.0 m/s 118 to 7,874 ft/min 2.2 to 144.0 km/h 1.3 to 89.5 mph 1.2 to 77.8 knots 0 to 12 B* 2-131.2*1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller
Ambient Temperature0.9 °F 0.5 °C0.1 °F 0.1 °C-20.0 to 158.0 °F -29.0 to 70.0 °CAirflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.
Relative Humidity2%RH0.1 %RH10 to 90% 25°C noncondensingTo achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
Pressure1.5 hPa|mbar 0.044 inHg 0.022 PSI0.1 hPa|mbar 0.01 inHg 0.01 PSI25°C/77°F 700-1100 hPa|mbar 20.67-32.48 inHg 10.15-15.95 PSIMonolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.
Compass1° 1/16th Cardinal Scale0 to 360°2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.

CALCULATED MEASUREMENTS
MEASUREMENTACCURACY (+/-)RESOLUTIONSENSORS EMPLOYED
Air Density0.0002 lb/ft3 0.0033 kg/m0.001 lbs/ft3 0.001 kg/m3Temperature, Relative Humidity Pressure
Air Flow6.71%1 cfm 1 m3/hr 1 m3/m 0.1m3/s 1 L/sAir Speed, User Input (Duct Shape & Size)
Altitudetypical: 23.6 ft/7.2 m from 750 to 1100 mBar max: 48.2 ft/14.7 m from 300 to 750 mBar1 ft 1 mPressure, User Input (Reference Pressure)
Barometric Pressure0.07 inHg 2.4 hPa|mbar 0.03 PSI0.01 inHg 0.1 hPa|mbar 0.01 PSI Pressure, User Input (Reference Altitude)
Crosswind & Headwind/Tailwind7.1%1 mph 1 ft/min 0.1 km/h 0.1 m/s 0.1 knotsWind Speed, Compass
Delta T3.2 °F 1.8 °C0.1 °F 0.1 °CTemperature, Relative Humidity Pressure
Density Altitude226 ft 69 m1 ft 1 mTemperature, Relative Humidity Pressure
Dew Point3.4 °F 1.9 °C 15- 95% RH. Refer to Range for Temperature Sensor0.1 °F 0.1 °CTemperature, Relative Humidity
Evaporation Rate0.01 lb/ft2/hr 0.06 kg/m2/hr0.01 b/ft2/hr 0.01 kg/m2/hrWind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature)
Heat Index7.1°F 4.0°C0.1 °F 0.1 °CTemperature, Relative Humidity
Moisture Content | Humidity Ratio (“Grains”)4.9gpp .7g/kg0.1 gpp 0.01 g/kgTemperature, Relative Humidity Pressure
Probability of Ignition (PIG)PIG Accuracy dependent on proximity of inputs to reference table steps.10%Temperature, Relative Humidity
THI (NRC)1.5 °F 0.8 °C0.1 °F 0.1 °CTemperature, Relative Humidity
THI (Yousef)2.3 °F 1.3 °C0.1 °F 0.1 °CTemperature, Relative Humidity
Relative Air Density.0.3%0.1%Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Psychrometric3.2 °F 1.8 °C0.1 °F 0.1 °CTemperature, Relative Humidity Pressure
Wet Bulb Temperature - Naturally Aspirated (NWB TEMP)1.4 °F 0.8 °C0.1 °F 0.1 °CWind Speed, Temperature Globe Temperature, Relative Humidity, Pressure
Wind Chill1.6 °F 0.9 °C0.1 °F 0.1 °CWind Speed, Temperature
ADDITIONAL PRODUCT INFO
Display & BacklightMultifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight.
Response Time & Display UpdateDisplay updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes.
Data Storage & Graphical display Min/Max/Avg HistoryLogged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
data Upload & Bluetooth Data Connect OptionWireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
Clock/CalendarReal-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Auto ShutdownUser-selectable – Off, 15-60 minutes with no key presses.
LanguagesEnglish, French, German, Spanish.
CertificationsCE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
OriginDesigned and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery LifeAA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use.
Shock ResistanceMIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
SealingWaterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature-22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included)
Details

Manual


  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会