- Output Power: 10kW maximum at full rated output voltage and current
- Output Voltage: Units available with maximum output voltages from 60 ~ 300kV
- Output Current: Up to 166 mA for 60 kV and 10 mA for 500 kV
- Input Voltage: 208 VAC ±10% (187 VAC ~ 229 VAC) 47 ~ 63 Hz 3 phase plus protective earth
- Minimum Voltage: 5% of rated output voltage. The unit may be turned down below this but the specifications are not guaranteed below this level.
- Calibration: Calibration between Voltage Demand, Output Voltage and Voltage Monitor ±0.2% of setting or ±0.05% of rating, whichever is greater
- Recovery Time: Less than 200 ms to within 0.1% of previous operating level following a short circuit or arc. Maximum overshoot 2% of rated output voltage
- Temperature Coefficient: Less than 100 ppm/°C
- Drift: Less than 0.01% per hour after 1 hour’s warm up, typically less than 0.02% per 8 hours after 1 hour’s warm up, at constant load, line and temperature
- Operating Temperature: 0°C ~ +40°C ambient and air intake
- Storage Temperature: -20°C ~ +85°C
- Humidity: 80% maximum relative humidity up to 31 Deg C, reducing linearly to 50% at 40 Deg C. Non-condensing (ref BSEN61010-1)
- Altitude: Sea level up to 2000 metres (6500 feet)
- Usage: Indoor use only
- Voltage Ripple:
Voltage Mode: Less than 0.1% of rated voltage +2 V, peak to peak or less than 0.02% of rated voltage +1 V, rms
Current Mode: Less than 0.5% of rated voltage peak to peak or less than 0.1% of rated voltage rms
- Voltage Regulation:
Line: Less than 0.01% +0.5 V change in output voltage for a 10% change in line voltage
Load: Less than 0.01% +0.5 V change in output voltage for 0 to 100% change in load current
- Current Regulation:
Line: Less than 0.5% of rated current for a ±10% change in line voltage
Load: Less than 0.5% of rated current for 0 to 100% change in output voltage
- Dimensions (W x D x H): 43 x 51.6 x 13.3 cm3 (17 x 20.3 x 10.5 in3)
- Weight:
Converter 27 kg (99 lb)
HV Stacks from 31 to 91 kg depending on output voltage variant
- Interface:
Remote Control Interface: Analog, control is via a 25-way female D-type connector
Optional digital RS232 remote control, 9-way female D-type connector available
- Options & Accessories
Positive or negative polarity
Front panel and control options
HV output cables available — 3 m, 5 m, or 10 m