Max. Power: 5600W
Max. Voltage: 260V
Max. Current: 40A
Working Frequency: DC,40~440Hz
1) Working Mode
+ Constant Current: 0.10~40A ; DC/50/60Hz:±(0.5% of setting + 0.3 % of measurement); 400Hz: ±(1.0 % of setting + 0.5% of measurement)
+ Constant Resistance: 1~100Ω ; DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement); 400Hz: ±(1.5 % of setting + 1.0% of measurement)
+ Constant Power: 10W~5600W; DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement); 400Hz: ±(2 % of setting + 1.0% of measurement)
2) Test
+ Voltage: 0~260V; DC/50/60Hz:±(0.5% of setting + 0.1 % of measurement); 400Hz: ±(0.5 % of setting + 0.1% of measurement)
+ Current: 0~40.00A; DC/50/60Hz:±(0.5% of setting + 0.2 % of measurement): 400Hz: ±(1.0 % of setting + 0.5% of measurement)
+ Power: 10W~5600W; DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement); 400Hz: ±(2% of setting + 1.0% of measurement)
3) Protection
+ Input Over Voltage: Max. 105%
+ Input Over Current: Max. 105%
+ Input Over Power: Max. 105%
+ Over Temperature: 85℃
4) Dimension: 482*356*460
5) Trọng lượng: 68 kg
Product Detail
With Basic working mode of constant current, constant resistance and constant power
Widely used in simulation tests for inverters such as transformer, UPS, AC inductive and capacity and rectification capacitive load
|
Model No. |
AN29201(F) |
AN29202(F) |
AN29203(F) |
AN29204(F) |
|||||
|
Working Conditions |
Working Power Supply |
AC 220V±10%,50/60Hz±5% |
|||||||
|
Environment Temperature |
0~40℃ |
||||||||
|
Relative Humidity |
20~90%RH40℃ |
||||||||
|
Measurement |
Max. Power |
1400W |
2800W |
4200W |
5600W |
||||
|
Max. Voltage |
260V |
||||||||
|
Max. Current |
10A |
20A |
30A |
40A |
|||||
|
Working Frequency |
DC,40~440Hz |
||||||||
|
Working Mode |
Constant |
Measurement |
0.10~10A |
0.10~20A |
0.10~30A |
0.10~40A |
|||
|
Resolution |
10mA |
||||||||
|
Allowed Maximum Error |
DC/50/60Hz:±(0.5% of setting + 0.3 % of measurement) |
||||||||
|
Constant |
Measurement |
1~400Ω |
1~200Ω |
1~130Ω |
1~100Ω |
||||
|
Resolution |
0.1 /1Ω |
||||||||
|
Allowed Maximum Error |
DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement) |
||||||||
|
Constant |
Measurement |
10W~1400W |
10W~2800W |
10W~4200W |
10W~5600W |
||||
|
Resolution |
1W |
||||||||
|
Allowed Maximum Error |
DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement) |
||||||||
|
Test |
Voltage |
Measurement |
0~260V |
||||||
|
Resolution |
100mV |
||||||||
|
Allowed Maximum Error |
DC/50/60Hz:±(0.5% of setting + 0.1 % of measurement) |
||||||||
|
Current |
Measurement |
0~10.00A |
0~20.00A |
0~30.00A |
0~40.00A |
||||
|
Resolution |
10mA |
||||||||
|
Allowed Maximum Error |
DC/50/60Hz:±(0.5% of setting + 0.2 % of measurement) |
||||||||
|
Power |
Measurement |
10W~1400W |
10W~2800W |
10W~4200W |
10W~5600W |
||||
|
Resolution |
1W |
||||||||
|
Allowed Maximum Error |
DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement) |
||||||||
|
Setting Range |
0°~±90° |
||||||||
|
Current Waveform Simulation |
Peak Factor Setting Range |
1.4~5 |
|||||||
|
Trigger Phaseshift Range |
(0°) ~(360°) |
||||||||
|
Dynamic |
Load On Time Setting Range |
5ms~10s |
|||||||
|
Load On Time Setting Error |
Max. 10us |
||||||||
|
Protection |
Input Over Voltage |
Max. 105% |
|||||||
|
Input Over Current |
Max. 105% |
||||||||
|
Input Over Power |
Max. 105% |
||||||||
|
Over Temperature |
85℃ |
||||||||
|
Dimension |
482*223*460 (W×H×D) |
482*356*460 |
|||||||
|
Weight(Kg) |
33 |
43 |
58 |
68 |
|||||
|
Optional Accessories |
RS232, RS485, GPIB, USB, Net gape, Single/ 3-phase Online and I-Monitor Interface |
||||||||