数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。
登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。
認定専門家へ直接アクセス
数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。
登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。
認定専門家へ直接アクセス

Generator (Receiver Test)
Port Protection Limit: 5 W for 30 seconds
Frequency Range: 1 MHz to 1 GHz (100 kHz to 1 GHz usable); Optional to 3 GHz
Extended Frequency Range (Optional): 1 MHz to 3 GHz (100 kHz to 3 GHz usable)
Frequency Resolution: 1 Hz
Output Level Generate Port
Range FM: +5 dBm to -95 dBm below 2 GHz; -5 dBm to -95 dBm above 2
GHz (Both to -125dBm with extended gen out range option)
Range AM: -1 dBm to -95 dBm below 2 GHz; -11 dBm to -95 dBm above 2
GHz (Both to -125dBm with extended gen out range option)
Resolution: 0.1 dB
Accuracy: ±2 dB
Output Level RF I/O Port
Range FM: -30 dBm to -130 dBm below 2 GHz; -40 dBm to -130 dBm above 2 GHz
Range AM: -36 dBm to -130 dBm below 2 GHz; -46 dBm to -130 dBm above 2 GHz
Resolution: 0.1 dB
Accuracy: ±1 dB to 1 GHz ; ±2 dB > 1 GHz
Spectral Purity
Harmonic Spurious: -20 dBc max
Non-Harmonic Spurious: -35 dBc max; <-25dBc at mixing product frequencies (3227MHz - Carrier) (-30dBc typ); 10MHz Harmonics <-124 dBm (RF I/O)
Residual FM: 4 Hz, 300 Hz to 3 kHz (<1 GHz); 5 Hz, 300 Hz to 3 kHz (> 1 GHz)
Residual AM: 1.0% max, 300 Hz to 3 kHz
SSB Phase Noise (20 kHz Offset): -95 dBc/Hz max below 1 GHz (15° to 35° C); -93 dBc/Hz max all frequencies (0° to 50° C)
Receiver (Transmitter Test)
Frequency Range: 1 MHz to 1 GHz (100 kHz to 1 GHz useable);
Optional to 3 GHz Sensitivity
Narrowband FM: 2.0 uV for 10 dB EIA SINAD
Wideband FM: 10 uV for 10 dB EIA SINAD
AM: 10 uV for 10 dB EIA SINAD RF I/O Port
VSWR: < 1.2 to 2 GHz, ˜ 1.5 to 3 GHz
Max Power:
50 W for 5 minutes
150 W for 30 seconds (30 sec. on, 5 min. off)
Absolute Max Power: 150 W
Alarm: Internal temperature alarm
Spectrum Analyzer
Sweep
Frequency Range: 1 MHz to 1 GHz (250 kHz to 1 GHz typical); Optional to 3 GHz
Frequency Resolution: 1 Hz
Span Accuracy: 5%
Update Rate: ~10 times per second (depending on span)
Oscilloscope
Vertical Input
Input Impedance: 1 Meg Ohm / 600 Ohm (Selectable)
Range: ±100 VDC, ±70 Vrms AC
Accuracy: 5% of full scale
Bandwidth: 0 to 50 kHz
Horizontal Sweep: Range: 20 uSec to 1 Sec / div. (Selectable)
Trigger Selection: Normal, Auto (Free Running), Single Sweep and Freeze
Special Functions: Markers: Absolute Voltage, Delta Voltage, Delta Frequency and Delta Period
*For detailed specifications, please refer to the datasheet.