For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Back-to-Basic Measurement Workshop

2018年07月20日 13時50分25秒

We would like to invite you to "Back-to-Basic Measurement Workshop" which co-organized by GW Instek and EMIN Viet Nam

We would like to invite you to participate in "Back-to-Basic Measurement Workshop".

The workshop is co-organized by EMIN Vietnam and Good Will Instek (GW Instek). Good Will Instrument Co. Ltd. (GW Instek)  has been a prestige manufacturer of testing and measuring equipment in the world since 1975, offers a wide range of products and solutions that enable accurate, long-term and reliable testing in the hardest testing environments.

Come to this workshop, you will know how to use optimally the equipments: Oscilloscope, Function generator, DC power and LCR meter . You will also be carefully guided to operate on the machine by foreign experts from GW Instek.

Toward the real experience, we chose the classroom layout, each three-person table has five instruments. Thus, you can have the opportunity to experience more real and better understand the information brought.

Time:  9:00 a.m - 4:30 p.m

  • Ha Noi city: 19, 20, 21 August
  • Ho Chi Minh City: 24, 25 August

Venue:

  • Hanoi: 4th floor, VIP3, Mipec Tower, 229 Tay Son, Ward Nga Tu So, District Dong Da, Hanoi, Vietnam
  • HCMC: Orchid 1, Ramana Saigon Hotel, 323 Le Van Sy, Ward 13, District 3, HCMC, Vietnam

Workshop Agenda:

9:00-9:20 Registration
9:20-9:30 Opening
9:30-10:45 Oscilloscope workshop (1 hr 15 min):
- Oscilloscope overview
- Control (vertical, horizontal, trigger)
- Measurement (manual, cursor, automated)
- Probe usage and compensation
10:45-11:00 Take a break
11:00-12:15 Function Generator workshop (1 hr 15 min):
- Function generator overview
- Signal generation (sine, square, pulse stream)
- Modulation
- Isolated channel
12:15-13:30 Lunch

13:30-14:45 DC Power Supply workshop (1 hr 15 min):
- Power supply overview
- Control (voltage, current)
- Cascading (series parallel)
- CC priority
14:45-15:00 Take a break
15:00-16:15 LCR Meter (1 hr 15 min):
- LCR overview
- Control (test function, voltage, frequency)
- Correction (open, short)
- Comparator (pass/fail)
16:15-16:30 Q&A

 


Any engineer, manager, scientist, academician or technocrat can attend this one day technical seminar.The audience

Note:

All activities of the program are free, including lunch, tea-break
- Speaking in English
- Each delagate only can register 01 day.
Your participation is free of charge, but seats are limited. If you have any queries about this event, please do not hesitate to contact us. 

Email: marketing@emin.vn

Tel: 024 35381 269
Mob: 0961531195 (Ms.Hanna)

We look forward to hosting you and your team members.

See GWinstek products here!

 

関連ニュース

Choosing Communication Interfaces for Test Equipment
2026年08月10日 15時39分24秒

A practical guide to selecting RS232, GPIB, LAN, USB, or Wi-Fi for test equipment based on connection range, networking needs, computer compatibility, and instrument control requirements.

Comparing Shore A and Shore D Hardness: Two Common Hardness Scales Today
2026年08月10日 14時16分08秒

Both Shore A and Shore D are used to measure material hardness, but each scale is suited to a different group of materials. Soft rubber, silicone, or elastic gaskets are typically tested using Shore A, whereas hard plastics, engineering plastics, and materials with low deformation are better suited to Shore D

What causes equipment to restart automatically in the factory, and how can the fault be identified?
2026年08月10日 11時17分47秒

Equipment restarts in a factory setting can be attributed to voltage sags, momentary power outages, electrical noise, overheating, or hardware faults. For incidents that last only a few power cycles, a power quality analyzer can capture voltage, current, and waveform data at the exact moment of the reset, thereby helping engineers determine whether the power supply is the cause

Why Measured Amplitude Is Lower Than the Real Value
2026年08月10日 09時28分50秒

An oscilloscope can display a lower amplitude than the true signal when its bandwidth is not high enough. This article explains bandwidth, the 5x rule, and rise time in practical terms.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス