For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

BKPRECISION HPS20K800-400V 高出力プログラマブルDC電源 (800V; 25A; 20 kW - 400 VAC)

VAT別
468,980,000 VND
VAT込
506,498,400 VND
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能

Output Rating: 

Output Voltage : 0 to 800 V

Output Current : 0 to 25 A 

Output Power : 20 kW

Line Regulation: 

Voltage : 160 mV 

Current:  5 mA 

Load Regulation: 

Voltage : 420 mV

Current : 33 mA 

Ripple and Noise (20 Hz to 20 MHz): 

Voltage p-p : 350 mV 

Voltage rms : 150 mV

Current rms(1) : 25 mA 

Readback Resolution: 

Voltage Range: 

20 V to 99.99 V:  10 mV

100.0 V to 999.9 V:  0.1 V

1000 V to 1500 V : - 

Current Range: 

0 A to 9.999 A : 1 mA

10.00 A to 25 A : 10 mA

Programming Accuracy: 

Voltage:  ≤ 800 mV 

Current : ≤ 50 mA 

Output Response Time(2): 

Rise Time: 

Full Load : ≤ 40 ms

No Load : ≤ 10 ms

Fall Time: 

Full Load : ≤ 60 ms 

No Load : ≤ 10 s

400 AC Input: 

Nominal Input : Voltage 400 VAC

Input Range : 360 to 440 VAC

Frequency : 47 to 63 Hz

Phase 3 phase: 

Protection: 

OVP Range:  0 to 960 V 

General: 

Remote Sense Compensation:  80 V

Transient Response Time(3) : ≤ 3 ms

Command Response Time(4) : 10 ms

Efficiency(5) : 0.94

Power Factor:  > 0.7

Output Terminal Isolation : 2000 V

Inrush Current(6) : 76 A

Leakage Current : < 35 mA

I/O Interfaces:  RS232, LAN,Analog (Galvanically isolated DB25)

Analog Programming (typical): Input impedance: 1 MΩ;  Maximum input voltage 25 V;  Response time < 10 ms

Temperature Ratings: 

+ Operation: 32 ºF to 122 ºF (0 ºC to 50 ºC)

+ Storage: -4 ºF to 158 ºF (-20 ºC to 70 ºC)

Operating Humidity : < 80%

Altitude : < 2000 m

Environment : Installation category II, pollution degree 2

Dimensions (W×H×D) : 19” x 5.3” x 24.2” (482 x 132.5 x 614.7 mm)

Weight: 82 lbs (37 kg)

Standard Accessories : Test report & certificate of calibration

Regulatory Compliance: 

Safety:  Low Voltage Directive (LVD) 2014/35/EU, EN61010-1:2010 + A1:2019

Electromagnetic Compatibility:  EMC Directive 2014/30/EU, EN61326-1:2013

(1) When output power > 1.0% of full power.

(2) From 10% to 90% or from 90% to 10% of total voltage excursion

(3) Time for output voltage to recover within 0.5% ±25 mV of its rated output.

(4) Typical time required for output to begin to change following receipt of command data.

(5) At nominal line voltage and max load.

(6) Applies to rated input voltage. The inrush current only occurs when first connecting to the grid.

Datasheet

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス