For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

CHROMA 61812 Regenerative Grid Simulator (12kVA)

お問い合わせ
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能

AC Output Power

+ Selectable single-phase or three-phase output

+ Maximum power: 12 kVA

+ Per-phase power: 4 kVA

Voltage

+ Voltage range: 0–350 V (Phase-to-Neutral) / 0–606 V (Phase-to-Phase)

+ Setting accuracy: ±(0.1% + 0.2% of full scale)

+ Resolution: 0.1 V

Maximum Current (Single-Phase Mode)

+ RMS: 96 A

+ Peak: 288 A

Maximum Current (Per Phase in Three-Phase Mode)

+ RMS: 32 A

+ Peak: 96 A

Frequency

+ Frequency range: 30–100 Hz

+ Accuracy: 0.01%

DC Output (Single-Phase Mode)

+ Power: 12 kW

+ Voltage: 495 V

+ Maximum current: 72 A

DC Output (Per Phase in Three-Phase Mode)

+ Power: 4 kW

+ Voltage: 495 V

+ Maximum current: 24 A

Input Specifications

+ Operating voltage range

3-phase 200–220 V ±10% (Line-to-Line), 47–63 Hz (100% power)

3-phase 380–480 V ±10% (Line-to-Line), 47–63 Hz (100% power)

+ Input current

Maximum 51 A/phase (3-phase 200–240 V)

Maximum 27 A/phase (3-phase 380–480 V)

+ Power factor: 0.98

Measurement

+ Voltage

Measurement range: 0–350 V (Phase-to-Neutral)

Accuracy: ±(0.1% + 0.2% of full scale)

+ Current

Peak measurement range: 288 A

RMS accuracy: ±(0.4% + 0.3% of full scale)

Peak accuracy: ±(0.4% + 0.6% of full scale)

+ Power

Accuracy: ±(0.4% + 0.4% of full scale)

Parallel Operation: Up to 20 units

Series Operation: Up to 2 units

Touchscreen Display: 5-inch LCD

Standard Interfaces: USB, LAN

Optional Interfaces: GPIB, CAN

Dimensions (H × W × D): 132.8 × 428 × 700 mm

Weight: 50 kg

Standard Accessories: Main unit

Datasheet


お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス