Special offer on industrial engine testing solutions from EMIN and Chauvin Arnoux

2026年02月12日 11時50分22秒

Starting in January 2026, EMIN, in collaboration with Chauvin Arnoux, will launch a promotional program for industrial motor system measurement and evaluation solutions. The program focuses on equipment used for testing electrical quality, power consumption, and motor operating conditions in factories.

Partnering with businesses to optimize performance and save energy starting in early 2026

Energy costs are becoming a tightly controlled factor in manufacturing operations. An inefficient motor system can increase power consumption, generate excessive heat, and reduce equipment lifespan. Regular inspections help detect losses, phase imbalances, voltage drops, or insulation leaks early, before problems occur.

Voltage, current, and harmonic analysis using CA 8345

The quality of the power supply directly affects the performance and durability of the motor. Unbalanced voltage, waveform distortion, or low power factor all increase losses and generate heat.

The Chauvin Arnoux CA 8345 power quality analyzer allows for the comprehensive recording of three-phase parameters including voltage, current, power, power factor, and harmonics. The device supports real-time data logging and detailed report generation, helping engineers accurately identify the causes of energy loss or abnormal motor vibrations. The measured data not only aids in troubleshooting but also serves as a basis for evaluating the effectiveness of power system improvements after optimization.

Record actual power consumption with PEL113

Motors in factories typically operate under varying load cycles. Electricity consumption during peak production hours differs significantly from that during off-load periods.

The Chauvin Arnoux PEL113 data logger and power meter, combined with the MA194-350 series module, allows for continuous monitoring of energy consumption over several days. Active power, reactive power, and power factor are fully stored for trend analysis.

The real-world data helps businesses identify the most energy-consuming motor groups and develop optimal plans with clear priorities.

CA 6543 tests insulation resistance, reducing the risk of motor failure

Insulation degradation is a common cause of short circuits and sudden machine shutdowns. Environmental factors, dust, and material aging all affect the insulation resistance of windings.

The Chauvin Arnoux CA 6543insulation resistance tester allows testing at various voltage levels, supporting the assessment of degradation trends over time. Measurement results enable maintenance departments to proactively plan maintenance before problems occur. Regular insulation testing provides greater long-term value than addressing issues after the motor has already failed.

CA 1823 and CA 1246 are used for monitoring thermal and environmental conditions

High temperatures reduce the efficiency and shorten the lifespan of bearings and windings. Measuring surface temperature with the Chauvin Arnoux CA 1823 device helps to detect hot spots in bearings or motor housings early.

In addition, environmental conditions such as humidity and dew point directly affect insulation and heat dissipation. The Chauvin Arnoux CA 1246 temperature, humidity, and dew point meter provides the necessary data to assess the installation environment and develop appropriate control solutions.

Solutions tailored to each factory model

Motor performance doesn't depend on a single measurement. Power quality, power consumption, insulation condition, and operating temperature need to be monitored in parallel for a complete picture.

EMIN now offers a full range of Chauvin Arnoux equipment for testing and evaluating industrial motor systems. Our technical team provides consulting support to help select the most suitable solution based on factory size and specific optimization goals, enabling businesses to clearly control energy costs and achieve more stable long-term operation.

関連ニュース

Measuring COD and TOC in Electroplating Wastewater Using a Benchtop Analyzer? What Sources of Error Should Be Avoided?
2026年10月13日 10時55分11秒

The current situation regarding electroplating wastewater analysis presents challenges: the wastewater contains acids, alkalis, and heavy metals (such as Cr, Ni, and Cu), alongside persistent cyclic organic compounds derived from brightening agents, anti-misting additives, and degreasing solvents. This complex composition causes significant fluctuations in COD levels depending on the specific process stage and production shift. Sending samples to external laboratories results in a delay of several days—by which time the biological treatment tanks or coagulation systems may have already been operating improperly for too long. Utilizing a benchtop COD analyzer on-site reduces this turnaround time to just a few hours, provided the user fully understands the specific sources of error associated with electroplating wastewater

How to Rapidly Reduce COD in Domestic Wastewater?
2026年10月13日 10時25分11秒

Wastewater treatment plants serving apartment complexes, buildings, and residential areas sometimes experience effluent COD levels approaching regulatory limits, particularly following sudden load surges or shortly before scheduled compliance sampling. QCVN 14:2025/BTNMT, applicable to domestic wastewater from September 1, 2025, sets COD limits based on discharge volume and the receiving water body, while allowing dischargers to choose between TOC and COD parameters

Challenges of Pressure Gauges in Hydrogen Environments
2026年10月12日 16時47分15秒

The global energy transition trend is driving industrial plants, chemical facilities, and renewable energy sites to integrate hydrogen as a strategic fuel source to achieve decarbonization goals. However, practical experience shows that traditional mechanical pressure gauges rapidly degrade in service life and experience dangerous failures when in direct contact with hydrogen environments.

The Trend of Eliminating Mechanical Pressure Gauges in Semiconductor Fabrication Plants
2026年10月12日 14時44分38秒

In semiconductor cleanrooms, a single microscopic dust particle or a tiny toxic gas leak is enough to ruin an entire wafer batch worth millions of dollars. This vital requirement is accelerating a complete transition from traditional mechanical pressure gauges to digital pressure sensors and electronic pressure gauges.

NH3 and H2S Monitoring in Building Garbage Rooms: Sensor Selection, Placement, and Threshold Settings
2026年10月12日 14時33分46秒

The waste storage chamber in a high-rise building is an enclosed space where the continuous decomposition of organic matter generates ammonia (NH3) and hydrogen sulfide (H2S)—often accompanied by methane and various odor-causing compounds. These gases pose a direct health risk to sanitation staff, spread odors into the building's general ventilation system, and corrode electrical cabinets, piping, and technical equipment. This article addresses the questions frequently raised by building managers, M&E engineers, and occupational safety personnel