Common problems in old sterilizers that need to be watched out for

2025年06月20日 09時08分36秒

Used autoclaves that have been operated for a long time will often encounter some unavoidable problems. So when encountering common problems with old autoclaves, what should users pay attention to and how should they handle them? EMIN invites you to learn more in the article below.

Common problems in old sterilizers after long-term use

Autoclaves are indispensable equipment in microbiology laboratories, often used to sterilize specimens and instruments at high temperatures (such as 121°C), helping to prevent contamination and ensure accurate experimental results. 

However, after a long period of operation, old autoclaves that have been used for many years often begin to develop errors, causing many inconveniences during operation. So what are these common problems?

Damaged resistor

The resistor is the main heating element in the autoclave, ensuring that the internal temperature always meets the requirements. After a long period of operation, the resistor may be corroded, covered with scale or accumulated with dust, reducing the heat generating capacity of the device.

When the resistor no longer ensures the heating function, the temperature and pressure control in the autoclave chamber may be distorted, affecting the sterilization efficiency as well as the overall operation.

Aging rubber seal

The rubber gasket surrounding the lid of the autoclave acts to prevent heat loss during the sterilization process. In equipment that has been used for many years, the rubber gasket can age and lose its elasticity, leading to heat leakage and reduced operating efficiency. Heat escaping slows down the sterilization process and poses a potential safety risk to the operator.

Lid lock is broken

In addition to the rubber gasket, the lid lock is also the part that keeps the pot lid tightly closed during operation. After many years of use, the lock on old sterilizers can be damaged, making the lid unable to close completely, thereby causing unsafe operation of the device.

Leaks at valves and pipes

Leaks in the valve or pipe of the autoclave will cause the device to not maintain the necessary tightness, directly affecting its ability to operate. Not only will the required pressure and temperature not be achieved, this problem also increases the risk of overheating and causing danger during use.

Related Posts: 

Is there any harm in using an autoclave?

How to use an autoclave and what are the uses you don't know?

Top 3 most popular autoclaves in 2023

Some things to note when operating old, long-used autoclaves

In order for autoclaves that have been used for more than 7 years to maintain good performance and provide stable sterilization results at a stable temperature, regular maintenance and inspection are essential. So what should operators pay attention to when using old equipment? 

- Regularly remove excess water remaining in the steam chamber every day and use purified water to minimize the risk of damage to the resistor. When the resistor is still good, the heat generation capacity will be stable, helping the device maintain the appropriate pressure and temperature throughout the operating cycle.

- Periodically clean the steam chamber and the pot lid every month to avoid dust accumulation, affecting the operation process. When detecting signs of rubber gasket loss or not ensuring tightness, it is necessary to replace it immediately to avoid heat loss and ensure the device always operates effectively. 

- Regularly check the tightness of the locking pins on the lid to ensure that the pot is always closed during operation. In addition, the lid closing operation must also be performed in the correct order to avoid breaking or warping the locking mechanisms.

- It is necessary to periodically monitor the temperature and pressure parameters at various points inside the autoclave using a specialized data logger with high accuracy.

- For autoclaves with integrated vacuum function, it is recommended to conduct leak testing, temperature and pressure control according to international standards such as UNI EN ISO 13060, using specialized equipment such as Tecnosoft PressureDisk Datalogger for accurate results.

関連ニュース

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026年11月14日 11時35分16秒

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026年11月14日 10時28分19秒

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026年11月13日 17時23分39秒

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026年11月13日 16時11分22秒

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026年11月13日 15時07分40秒

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス