CS Instruments VA 520 流量計 (1“ measuring section, 1.4301 steel, 290m3/h)

ModelVA 520
P/N0695 0523
保証1 年
お問い合わせ
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能

Parameters: m³/h, l/min (1000 mbar, 20°C) in case of compressed air or Nm³/h, Nl/min (1013 mbar, 0 °C) in case of gases

Units adjustable via keys at display: m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h

Sensor: Thermal mass flow sensor

Measured medium: Air, gases

Gas types are adjustable over CS service software or CS data logger: Air, nitrogen, argon, CO2, oxygen

Measuring range: See table above 

Accuracy: (o. M. V. = of measured value) (o. F. S. = of full scale)

± 1.5% o.m.v. ± 0.3% o.f.s. 

± 1% o.m.v. ± 0,3% o.f.s.

Operating temperature: -30…80 °C

Operating pressure: -1 to 16 bar optionally up to PN 40

Digital output: RS 485 interface, (Modbus-RTU), optional: Ethernet interface PoE), M-Bus

Analogue output: 4…20 mA for m³/h or l/min

Supply: 18…36 VDC, 5 W

Burden: < 500 Ω

Housing: Polycarbonate (IP 65)

Measuring section: Stainless steel, 1.4301