What should you keep in mind when moving a laboratory scale?

2024年09月09日 08時34分08秒

What's special about laboratory scales? What should you pay attention to when moving a laboratory scale to another location? To answer this question, follow EMIN's article below


Concept of laboratory scales

The weighing experiment is an indispensable equipment in standard laboratories, where scientific research experiments take place. These balances are specially manufactured to serve the needs of laboratories and scientific research centers. We often use electronic scales capable of balancing small samples with very high accuracy.

Laboratory balances are called by many different names based on their capabilities and functions, analytical balances, technical balances, microbalances, and ultra-microbalances. Most of these scales have main functions and a screen that displays clear results. In addition, many website models still have the ability to connect to computers or printers, helping users easily manage and use information conveniently and effectively.

What problems do you often encounter when moving a balance in the laboratory?

Although moving equipment around in the laboratory is usually quite normal, laboratory scales are a notable exception. Moving a laboratory balance can lead to two main problems:

1. Loss of balance calibration: The laboratory balance is calibrated to a specific position at the time of calibration. Moving the scale can change conditions and lead to loss of calibration, reducing scale accuracy.

2. Damage to the spring or weight sensor: The weight sensor and spring in the laboratory balance are very sensitive to movement. Improper movement can cause overload and damage to these parts.

How to properly move a laboratory balance

Must see if location is suitable:

When moving the scale, choosing a new location is very important to ensure the durability and longevity of the scale. Here are some guidelines to pay attention to:

- Flat and stable surface: Place the scale on a flat and stable surface to avoid fluctuations and erroneous results.

- Avoid drafts and doors: Make sure the scale is placed away from drafts, next to doors or strong air currents.

- Avoid vibrating equipment: Do not place the scale near equipment that creates vibrations such as centrifuges or refrigerators, because vibrations can affect the accuracy of the scale.

- Non-harsh environment: Place the scale in an environment without extreme temperatures or humidity to ensure the durability and accuracy of the device.

- Clean area: The area where the scale is placed should be kept clean, avoiding excessive dust and dirt as dust can affect the weighing results.

If the scale has a lock, lock it before moving

Lock the scale if applicable: Some manufacturers design locks on the scales to protect them during transportation. When the lock is activated, the springs and load cells are released, protecting them from the forces caused by movement. Therefore, before moving the scale, you should lock these details (if your scale has this feature). 

- Turn off the power: Before unplugging the power, make sure the scale is completely powered off.

- Locking elements: Use locking mechanisms on the scale to ensure that the spring and load cell are not affected during movement.

Lift weight properl

When you are ready to move the scale, make sure you lift it from underneath. Lifting from upper components can stress and damage internal mechanisms. Lifting from below helps distribute force evenly, protecting important parts and ensuring the scale is not damaged during movement.


Pack carefully if moving the scale


If you plan to move the scale to another location and need to transport it, pack the scale very carefully. The laboratory balance should be placed in a box with foam padding or soft fabric to protect it from impact and vibration during transportation. This will help maintain calibration and prevent damage to the scale.


Rebalance the scale after the relocation is complete


Once the scale has been placed in its new position, the first thing to do is to adjust the scale so it is ready to work. Most laboratory scales have leveling indicators and adjustable feet. Rotate these pins until the bubbler is in a level position to ensure accuracy in future measurements.


Conclude:


Above are my shares about moving the laboratory scale properly. Please read the steps carefully to avoid unnecessary errors. Follow EMIN's fanpage to update the latest news


 

関連ニュース

Which Vacuum Pump Should You Choose for a Microbiology Lab to Avoid Affecting Samples?
2026年07月15日 14時45分07秒

Vacuum pumps are utilized in a wide range of microbiology laboratory procedures, from membrane filtration and the aspiration of supernatants following centrifugation to sample concentration and the support of negative-pressure systems. Selecting the appropriate pump not only ensures more stable operational processes but also minimizes the risk of sample contamination, reduces maintenance costs, and extends the equipment's lifespan

QCVN 25:2025/BKHCN Takes Effect: Do Businesses Need to Prepare Electrical Safety Testing Equipment?
2026年07月15日 09時15分04秒

Electrical safety is consistently one of the primary criteria evaluated before electrical or electronic equipment—or industrial components—are released to the market. A product may operate reliably yet still fail to meet requirements if its insulation lacks sufficient durability, its grounding resistance exceeds permissible limits, or leakage current occurs during operation.

Why Is Associated Research Considered an Icon of Hipot Technology?
2026年07月14日 09時05分30秒

When it comes to electrical safety testing equipment specifically Hipot testers—many QA/QC and testing engineers are familiar with the globally renowned brand Associated Research. A subsidiary of the parent company IKONIX, Associated Research (ARI) invented the world's first commercial Hipot tester.

What Is the Standard 3-Phase Voltage? How to Read Cabinet-Mounted Meters Without Errors
2026年07月13日 15時09分18秒

Voltmeters are almost invariably found on the panels of electrical cabinets in factories, power stations, or generator systems. A glance lasting just a few seconds allows an operator to determine whether the power supply is stable or showing signs of abnormality. However, not everyone understands the significance of the displayed readings, particularly regarding three-phase electrical systems.

Distinguishing between ARI’s Hypot, HypotUltra, and HypotMax: Which device is right for your factory?
2026年07月13日 09時48分30秒

Few people realize that the concept of the "Hipot Test"—or electrical safety testing—has long existed within the electrical equipment manufacturing industry. Driven by the growing need to verify the voltage withstand capabilities of conductors, motors, and electrical devices, the industry required a robust and virtually fail-safe method to detect insulation weaknesses before products reached the market.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス