For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

What is low voltage electricity? What are the current regulations regarding safe distances for low voltage electricity?

2026年01月15日 10時24分40秒

In electrical systems, low voltage is the most commonly used voltage level, appearing directly in residential homes, factories, and commercial buildings. Understanding the concept of low voltage and knowing safe distances helps reduce the risk of electrical accidents during use and construction.

What is low voltage electricity?

Low-voltage electricity is an electrical system with a low voltage level, below 1.1 kV according to Vietnamese standards. In practice, low-voltage electricity usually operates at 220 V and 380 V, supplying power to households, offices, shops, small workshops, and public lighting systems.

Low-voltage electrical systems typically use insulated wires, twisted-pair cables, or PVC-coated cables, installed on concrete poles or underground depending on the area. Compared to medium and high voltage electricity, low-voltage electricity has a lower level of danger but still poses risks if safety regulations are not properly followed.

Safe distance for low voltage electricity

According to applicable electrical safety regulations, overhead low-voltage power lines must maintain a minimum distance from people and surrounding structures to minimize the risk of electrical contact and discharge.

The minimum safe distance for low-voltage power lines is 0.3 m from the conductor to a person or object. This is the smallest limit for the electrical safety protection corridor; no residences or construction works should be located within this area.

At locations where low-voltage power lines intersect with roads, the distance from the lowest point of sag of the conductor to the road surface must be at least 4.5 m. This regulation aims to ensure the safety of vehicles and road users.

At intersections with operating railways, the safe distance at the lowest point of sag of the low-voltage power line must be 7.5 m or more, combined with the discharge distance according to technical standards.

On inland waterways, safe distances are determined by the clearance height of the channel, ensuring that no collisions occur between vessels and power lines.

Some safety regulations to note.

Construction projects located near low-voltage power lines must not have awnings, balconies, or metal structures that violate the electrical safety corridor. When repairing, renovating, or adding floors to a building, the distance from the existing power lines must be re-checked.

The safe distance for insulated conductors is usually greater than 1 meter. For bare conductors without insulation, the minimum safe distance required is 2 meters.

Organizations and individuals using equipment or means that damage power lines are liable for compensation and will be subject to legal penalties, depending on the severity of the violation.

Testing and measuring low voltage in practice.

To ensure the stable and safe operation of low-voltage electrical systems, regular voltage and current checks are necessary, especially in areas with frequently changing loads.

Some of the low-voltage electrical measuring devices currently distributed and used by EMIN include:

Digital multimeters are used to measure low-voltage voltage and quickly check the condition of power sources, such as the Hioki DT4256 or Kyoritsu 1109S. These devices effectively meet the needs for measuring AC and DC voltage in residential and light industrial electrical systems.

Low-voltage clamp meters allow for load testing without interrupting the circuit, suitable for maintenance and quick testing, such as the Hioki 3280 10F or Kyoritsu 2002PA. These models are widely used due to their stability and simple operation.

Conclude

Low-voltage electricity is a familiar voltage level, but one cannot be complacent during its use and installation. Strictly adhering to safe distances from low-voltage power lines and regularly inspecting the system with appropriate measuring equipment are crucial factors in minimizing accidents and protecting people and property.

関連ニュース

Choosing Fans, Heatsinks, Heat Spreaders, or Thermal Paste for High-Performance Electronic Devices
2026年11月09日 13時50分49秒

SiC and GaN semiconductor components feature high power density and compact dimensions, causing heat to be concentrated within a very small chip area. The question of which thermal management solution is most widely used is often framed as a choice between four options: fans, heatsinks, thermal pads, or thermal grease. This framing requires some refinement, as these four components occupy different positions along the same heat-transfer path; in fact, most designs employ a combination of several of these elements. This article explains the role of each component, how to select thermal interface materials, and the impact of temperature on measurements.

EMIN GROUP AT VIMF BAC NINH 2026
2026年11月07日 10時52分42秒

EMIN GROUP participated in the Vietnam Industrial & Manufacturing Fair 2026 (VIMF Bac Ninh 2026), held from November 4 to 6, 2025, at Kinh Bac Cultural Center in Bac Ninh City.

How Do Bidirectional DC Power Supplies Improve EV Testing?
2026年11月07日 09時57分58秒

Bidirectional DC power supplies combine source and sink operation in one platform. This supports realistic EV battery cycling, regenerative energy handling, programmable test sequences, and flexible battery or charger emulation.

Which Safety Features Should a High-Power DC Electronic Load Have?
2026年11月07日 09時57分16秒

For safer high-power DC testing, assess five protection functions: OVP, OCP, OTP, reverse-polarity protection, and short-circuit/fault protection. Together, they address abnormal voltage, current, heat, wiring, and system-fault conditions.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス