For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Gigahertz-Optik BTS2048-UV UV分光放射計 (190 - 430 nm)

ModelBTS2048-UV
P/N15298858
原産地Germany
お問い合わせ
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能

-Measurement range:


3E-5 W/(m²nm) to 3E4 W/(m²nm) @325nm. Responsivity from 190 nm to 430 nm.


-Typical applications:


CCD spectroradiometer for design applications. Module for integration in test systems for front-end and back-end LED testing.


-Calibration:


Factory calibration. Traceable to international calibration standards.


-Typical applications:


Lightmeter for spectral Irradiance, Erythema, etc.


-Measured Quantity:


Spectral irradiance (W/(m² nm)), irradiance (W/m²), peak wavelength, center wavelength, centroid wavelength, Erythema. Option integrating sphere: in addition spectral radiant power (W/nm) and radiant power (W)


-Input optics: Diffusor, cosine corrected field of view (f2 ≤ 3 %)


-Filter wheel: 4 positions (open, closed, optical filters). Use for remote dark current measurement and stray light reduction.


-BiTec:


Parallel measurement with diode and array is possible, thereby linearity correction of the array through the diode and online correction of the spectral mismatch of the diode through a*(sz(λ)) respectively F*(sz(λ)).


-Measurement modes:


Standard measurement mode: 200 nm to 430 n


Out of Range stray light corrected measurement mode (OoR SLC): 200 nm to 430 nm


Stray light corrected bandpass measurement mode (BP SLC): 300 nm to 386 nm


-Spectral detector:


+Integration Time: 2 μs - 60 s        


+Spectral range: (190 - 430) nm


+Optical Bandwidth: 0.8 nm


+Pixel resolution: ~0.13 nm/Pixel


+Number of pixels: 2048


+Chip: Highly sensitive back-thinned CCD chip, one stage cooled (1TEC)


+ADC: 16bit (25 ns instruction cycle time)


+Peak wavelength: ± 0.05 nm


+Band-pass correction: mathematical online band-pass correction is supported


+Linearity: completely linearized chip >99.6%


+Stray Light: Out of Bound method < 1E-4           


+Base line noise: 5 cts     


+SNR: 5000        


+Dynamic range: >9 Magnitudes


+Spectral responsivity: (3E-5 - 3E4) W/(m²nm) @325nm        


-Integral detector: 


+Measurement time: (0.1 - 6000) ms


+Measurement range: seven (7) measurement ranges with transcendent offset correction


+Calibration: Irradiance ± 6 %               


+ADC: 16bit


+Measurement range: 


Optional: (5E-3  -  2E5)  W/m² 


-Microprocessor: 32bit for device control,16bit for CCD array control, 8bit for photodiode control


-Interface: USB V2.0, Ethernet (LAN UDP protocol), RS232, RS485


-Data transfer: Standard for 2048 float array values via ethernet 7ms, via USB 2.0 140 ms


-Input Interfaces: 2x (0 - 25) VDC, 1x optocoupler isolated 5 V / 5 mA


-Output Interfaces: 2x open collector, max. 25 V, max. 500 mA


-Trigger: Trigger input incorporated (different options, rising/falling edge, delayed, etc.)


-Software:


User software S-BTS2048


Optional software development kit S-SDK-BTS2048 for user software set-ups based on .dll‘s in C, C++,C# or in LabView.


-Power Supply:


With power supply: DC Input 5V (±10 %) at 700 mA


With USB bus (500mA) *8


-Dimensions: 103 mm x 107 mm x 52 mm (Length x Width x Height)


-Weight: 500 g


-Mounting:


Tripod and M6 screw threads


Front adapter UMPA-1.0-HL for use with integrating sphere port-frame UMPF-1.0-HL


-Temperature range:


Storage: (-10 to 50)°C


Operation: (10 to 30)°C 

 Datasheet

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス