For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

How Does a UV-Vis Spectrophotometer Detect Counterfeit Products?

2026年07月10日 09時58分31秒

Learn how a UV-Vis spectrophotometer helps identify counterfeit products through sample preparation, absorbance spectrum measurement, reference sample comparison, and result analysis.

A UV-Vis spectrophotometer detects counterfeit products through a systematic analytical process that includes sample preparation, absorbance spectrum measurement, comparison with a reference sample, and evaluation of differences in peak position, absorbance intensity, and overall spectral profile. When two products differ in chemical composition, their UV-Vis spectra will almost always show measurable differences.

UV-Vis spectrophotometers are widely used in the analysis of food, pharmaceuticals, cosmetics, and chemical products.

Step 1 – Prepare the Sample for Analysis

  • Proper sample preparation is essential to obtain reliable results.

  • Collect a representative sample.

  • Dissolve the sample using the appropriate solvent.

  • Filter the solution if suspended particles or sediment are present.

  • Dilute the sample to the required concentration.

Step 2 – Measure the Absorbance Spectrum of the Suspected Sample

The UV-Vis spectrophotometer scans the sample to obtain its absorbance spectrum.

The procedure typically includes:

  • Placing the sample into a cuvette.

  • Selecting the wavelength range (for example, 190–800 nm).

  • Scanning the entire spectrum.

  • Recording the absorbance curve.

Step 3 – Measure an Authentic Sample to Create a Reference Spectrum

The spectrophotometer compares the test sample with an authentic product or a reference spectrum stored in a spectral library.

Many manufacturers build spectral libraries by measuring all qualified raw materials and approved finished products. This practice significantly reduces the risk of introducing substandard or counterfeit materials into the production process and provides a reliable benchmark for future quality inspections.

Labomed UV-Vis Spectrophotometer

Step 4 – Overlay the Two Spectra to Identify Differences

The operator compares the spectrum of the test sample with the reference spectrum on the display of UV Vis spectrophotometer and looks for signs of inconsistency.

Absorption peaks appear at different wavelengths

→ The chemical composition may have changed.

Lower absorbance intensity

→ The active ingredient may have been diluted or reduced.

Additional absorption peaks appear

→ Different additives or impurities may be present.

Changes in the overall spectral profile

→ The formulation differs significantly from the authentic product.

Step 5 – Perform Quantitative Analysis When Counterfeiting Is Suspected

If significant spectral differences are observed, laboratory personnel can perform quantitative analysis and compare the results with the manufacturer's specifications.

Typical procedures include:

  • Measuring absorbance at the characteristic wavelength.

  • Creating a calibration curve.

  • Calculating the concentration of the active ingredient.

Using a UV Vis machine provides a fast, non-destructive screening method for detecting potentially counterfeit products. It is particularly effective for quality control of both raw materials and finished products before they are released to the market.

関連ニュース

Errors in Measuring Rebar Diameter within Concrete
2026年11月23日 13時50分41秒

In the quality assessment of reinforced concrete structures using non-destructive testing (NDT) methods, determining the diameter (d) of reinforcing bars directly on a completed structural element often results in significantly greater margins of error compared to measuring the thickness of the concrete cover. If the identified diameter deviates by one or two standard size increments (for example, if a D16 bar is misidentified as a D20 or D12), the entire analysis—including the calculation of load-bearing capacity and the verification of the structural design—loses its reliability.

Assessment and Retrofitting of Reinforced Concrete Structures After Fire Exposure in Accordance with TCVN 14104:2025
2026年11月23日 11時48分42秒

In accordance with the principles for the preservation and post-fire structural assessment stipulated in TCVN 14104:2025, the inspection entity must accurately quantify the extent of cross-sectional degradation in heat-exposed concrete, the presence of subsurface delamination, and the condition of the internal steel reinforcement before developing a strengthening plan.

Causes of gas sensor errors
2026年11月21日 09時15分27秒

this silent loss of sensitivity typically stems from selecting the wrong sensing principle for the local chemical composition and atmospheric conditions. To effectively deploy equipment from our fixed gas detectors catalog, M&E engineers and HSE teams must understand the mechanisms behind catalytic sensor poisoning and identify the appropriate alternative technologies for each operating environment.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス