For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Metrel MD 9235 Clamp Meters (TRMS,600.0 V; 40.00 A … 600 A)

お問い合わせ
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能

Range/ Accuracy

DC Voltage: 600.0 V / ±(0.5% of reading + 5 digits)

AC Voltage (50 Hz … 3.1 kHz): 600.0 V / From ±(0.5% of reading + 5 digits) to ±(2.5% of reading + 5 digits)

AC Current (40 Hz … 3.1 kHz): 40.00 A … 600 A / From ±(1.0% of reading + 5 digits) to ±(3.0% of reading + 5 digits)

Resistance: 999.9 Ω / ±(1.0% of reading + 6 digits)

Apparent Power:

Range: 0 kVA … 600.0 kVA

Accuracy:

±(2.0% of reading + 6 digits), H 1./10.

±(3.5% of reading + 6 digits), H 11./46.

±(5.5% of reading + 6 digits), H 46./51.

Active Power, Reactive Power:

Range: 0 kW/kVar … 600.0 kW/kVar

Accuracy:

From ±(2.0% of reading + 6 digits) to ±(10.0% of reading + 6 digits), H 1./10.

From ±(3.5% of reading + 6 digits) to ±(10.0% of reading + 6 digits), H 11./25.

From ±(4.5% of reading + 6 digits) to ±(15.0% of reading + 6 digits), H 26./45.

From ±(10.0% of reading + 6 digits) to ±(15.0% of reading + 6 digits), H 46./51.

Power Factor (PF):

0.10 … 0.99 / ±3 digits, H 1./21.

0.10 … 0.99 / ±5 digits, H 22./51.

Mains Frequency: 5 Hz … 500 Hz / ±(0.5% of reading + 4 digits)

Power Supply: 2 × 1.5 V AAA batteries

Overvoltage Category: CAT IV / 300 V, CAT III / 600 V

Dimensions: 189 × 78 × 40 mm

Weight: 192 g

Datasheet

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート