New product! Optimize your leak detection process with the Fluke SB140 Sound Beacon

2025年07月18日 15時13分09秒

In non-pressure leak testing processes, leak detection is often difficult due to the lack of clear signals and difficulty in accessing the area to be tested. The Fluke SB140 is a new solution, using ultrasonic sound emitted from the inside to support faster and more intuitive leak detection with Fluke ultrasonic cameras. The product promises to significantly improve the accuracy, testing speed and operating efficiency for industries requiring high standards of tightness such as aviation, automotive, cleanroom or construction engineering.

Why are non-applied leaks difficult to detect and control?

In many non-pressurized systems, leaks are often overlooked due to the lack of differential pressure to create a flow of gas. This makes it difficult to detect errors with traditional measurement methods such as pressure decay. Small leaks also only release tiny amounts of gas or sound, which are difficult to observe with the naked eye or with simple tools such as foam spray. 

In addition, old testing methods are often time-consuming, depend on manual operations, and are not accurate enough in complex environments. Meanwhile, a small leak in an aircraft cabin, clean room or electric car compartment can lead to serious performance or safety consequences if not detected in time.

How does the Fluke SB140 Sound Beacon perform in tightness testing?

The Fluke SB140 Sound Beacon  offers a completely new leak testing method, especially optimized for non-pressurized systems such as vehicle compartments, tanks, aircraft cabins or clean rooms. Instead of using compressed air or liquid to test for leaks like traditional methods, this device utilizes high-frequency ultrasonic waves to accurately detect the location of leaks.

The operation begins with the SB140 Sound Beacon  device placed inside the volume to be tested. Thanks to its compact size and robust design, the device can be easily placed in a variety of spaces. When operating, the SB140 Sound Beacon emits ultrasonic waves at a frequency of 40kHz, which is the optimal frequency for transmission through the air with minimal signal loss.

If there are any gaps in the internal volume, the sound waves will leak out through points such as loose welds, aging rubber gaskets, assembly joints or small cracks that are difficult to observe with the naked eye. It is at these locations that the escaping ultrasonic waves will be detected by an ultrasonic imager such as the ii500, ii905 or ii915 and displayed visually on the screen.

This combination allows users to quickly locate leaks in just minutes without destroying the sample or affecting the structure of the device. In particular, with Beacon Mode, the camera will automatically focus on the frequency emitted by the SB140, helping to eliminate background noise and highlight the sound stream that is escaping. This makes it easy for technicians to accurately locate leaks, even in environments with a lot of noise or high reflection.

The effectiveness of this method lies in its ability to detect leaks without creating differential pressure, an important factor for systems that cannot withstand compression or where non-invasive testing is required. This is also why the Fluke SB140 Sound Beacon is increasingly chosen for demanding applications in aerospace, automotive, home appliances and clean rooms.

Explore Beacon Mode for intuitive ultrasound display, find leaks faster

Beacon Mode is the newest feature that helps the SB140 Sound Beacon maximize its working efficiency. This mode automatically locks on the correct 40kHz transmission frequency, eliminates background noise and focuses on displaying the exact leak sound flow as a wave cloud on the Fluke device. As a result, even non-technical users can easily identify and locate leaks, even when inspecting complex structures or noisy environments.

Why is the Fluke SB140 Sound Beacon a worthwhile investment for modern tightness testing?

As quality control procedures become more advanced and non-invasive requirements become the norm in many industries, the Fluke SB140 Sound Beacon has proven to be an indispensable leak tester. Instead of relying on compressed air or liquid to create test pressure, the SB140's method allows for leak detection via high-frequency ultrasonic waves, ensuring safety, no internal pressure, and no disruption to the system structure.

It does not work alone, when combined with Fluke's sonic imager, the SB140 Sound Beacon opens up a whole new experience in leak testing. Users simply place the device in the volume to be tested and use the external sonic camera to monitor the entire process. The ultrasonic stream escaping at the leak location will be clearly and intuitively displayed on the screen, without the need for guesswork or multiple checks as before. 

Investing in the Fluke SB140 Sound Beacon is more than just adding another piece of testing equipment; it’s a complete upgrade in how businesses approach leaks. It makes leak testing more accessible, faster, and more accurate. That’s why the SB140 Sound Beacon is poised to become the go-to tool for modern quality inspection.

SB140 is widely used in aviation, automobile, clean room, construction...

While each industry has its own standards for leak testing, they all require a method that is accurate, fast, and non-destructive. The Fluke SB140 Sound Beacon meets these requirements, thanks to its stable ultrasonic output and easy integration with the ii500, ii905, and ii915 series of ultrasonic cameras. 

In the aerospace industry, pressure cabins and systems such as pitot-static require periodic leak testing to ensure flight safety. Timely detection of even a small leak can help prevent pressure deviations that can seriously impact performance and safety. The SB140 Sound Beacon allows technicians to perform quick checks during maintenance or inspection of outputs without complicated disassembly.

The automotive industry is also seeing an increased need for non-invasive testing, particularly in electric vehicle battery compartments or automatic window systems. The SB140 Sound Beacon helps manufacturers identify leaks early that could cause water infiltration, sound loss or compromise component durability. Its fast testing speed and simple operation make it suitable for on-line testing, from passenger cars to heavy trucks.

For cleanrooms where any gap can affect microbiological conditions or pressurized air flow, the SB140 Sound Beacon becomes an ideal inspection solution. With stable transmission and visual display via camera, operators can directly monitor and immediately address leaks in a single scan.

In the construction industry, the device helps to accurately identify leaking locations in doors, glass frames, walls or ventilation systems. This is the basis for improving soundproofing, insulation and reducing energy loss. Construction units or building managers can use the device for post-installation, handover or periodic maintenance inspections. 

From aviation to civil, the SB140 Sound Beacon not only saves users time but also enhances reliability and professionalism throughout the entire leakproofness testing process. Early and accurate detection of faults also means reduced warranty costs, risk avoidance and improved product quality.

Conclusion

This is why leak detection in non-applied systems needs to be done seriously and correctly – not only to ensure performance but also as a safety factor that is key in many areas.

The Fluke SB140 Sound Beacon offers a simpler, faster and clearer method of leak testing. With accurate detection without the need for differential pressure, this device makes the job easier for technicians and increases the reliability of each step of the test.

In the context of increasingly stringent technical requirements, choosing the right tool is no longer a priority but a must to ensure quality and long-term operational efficiency.

関連ニュース

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026年11月14日 11時35分16秒

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026年11月14日 10時28分19秒

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026年11月13日 17時23分39秒

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026年11月13日 16時11分22秒

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026年11月13日 15時07分40秒

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス