Working dimension: L800mm*W800mm*H800mm
Outer dimension: L1250mm*W1020mm*H1770mm
Temperature range: RT+10~+40℃
Temperature evenness: ≤2℃
Temperature fluctuation: ≤±0.5℃
Humidity: 45%-75%
Wire diameter of metal net: 50μm
Wire interval: 75μm
Airflow velocity: ≤ 2.5m/s
Time range: 0~999H(adjustable)
Vibration Time: 0-999H(adjustable)
Time Accuracy: ±1s
Dust concentration: 2~4kg/m3
Sand and dust: talcum powder, dry powder, portland cement paste
Vacuum degree: 0-10Kpa (adjustable)
Evacuation speed: 0-60L/H (adjustable)
Circulatory system: Dust recycling
Powder spraying and dust reduction method: Free
Working condition: Temperature:15℃ ~35℃ , humidity:≤85%R.H., pressure: 86kPa~106kPa
Configuration: Observe window equip with window wiper, lamp, metal sieve, 2KG talcum powder and etc.
Power socket for EUT: IP66, 220V/16A
Power supply: 1.5KW, AC220V±10%, 50Hz (single phase)
Dust chamber is designed according to the standards of GB/T10485-2007, GB2423.37-2006 test L, GB208-2008, IEC60529 (IP code), GB7001-1986 and etc..
Dust chamber is for IP5X and IP6X testing, the power shall be able to pass through a square-meshed sieve the nominal wire diameter of which is 50μm and the nominal width of a gap between wires 75 μm.
The dust chamber is controlled by 7 inch touch screen and PLC system. The interior of the cabinet is equipped with lighting and power supply, which can be used for live dust-proof test of the sample to simulate a more realistic use environment. There is a mesh sample support plate inside the box for Dust recycling, it is made of stainless steel and has a load capacity of 50KG. Operation video: https://youtu.be/xEe--St0Yzo
IP5X dustproof test chamber: the protection is satisfactory if the power has no accumulated in a quality which may interface the correct operation and cause harmful to equipment.
IP6X dustproof test chamber: the protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test