Polimaster PM1703GNB 分光パーソナル放射線検出器
お問い合わせ
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能
- Detector:
+ gamma CsI(Tl)
+ Neutron: Li6I (Eu) - Sensitivity:
+ for 137Сs, no less 100 (s-1)/(μSv/h) (1.0 (s-1)/(μR/h))
+ for 241Am, no less 200 (s-1)/(μSv/h) (2.0 (s-1)/(μR/h))
- Energy range:
+ gamma 0.033 – 3.0 MeV
+ Neutron: from thermal to 14.0 MeV
- Dose Rate:
+ gamma 0.01 – 99.99 μSv/h (1 – 9999 μR/h)
+ Neutron: 1 - 999 s-1
- Dose:X
- Accuracy: ±30% (in range 0.1 – 70 μSv/h (10 – 7000 μR/h) (at 137Cs))
- Response time: 0.25 s
- Radionuclide identification:
+ Special nuclear materials (SNM): 233U, 235U, 237Np, Pu
+ Medical radionuclides: 18F, 67Ga, 51Cr, 75Se, 89Sr, 99Mo, 99mTc,103Pd, 111In, 123I, 131I,153Sm, 201Ti, 133Xe
+ Naturally occurring radioactive materials (NORM): 40K, 226Ra, 232Th and daughters, 238U and daughters
+ Industrial radionuclides: 57Co, 60Co, 133Ba, 137Cs, 192Ir,
226Ra, 241Am
- Standards compliance: ITRAP/IAEA requirements, ANSI N42.32, ANSI N42.33(1), IEC 62401
- Alarm type: visual, audio, vibration
- Data recording: 1000
- Environmental protection: IP65
- Drop test on concrete floor: 1.5 m (4.9 ft) 0.7 m (2.3 ft) without cover
- Power supply: one AA battery
- Battery life time: up to 1000 hours
- Operating temperature: -30°C to 50°C (-22°F to 122°F)
- Size (without holster): 75 x 35 x 98 mm (2 15/16 x 1 3/8 x 3 7/8 )
- Weight (without holster): 230 g (8.1 oz); (with holster): 270 g (9.5 oz)
- Low battery warning: LCD
- Overload indication:
+ gamma OL
+ Neutron:999
- PC Communication: IRDA, Bluetooth
The family of Polimaster Gamma and Gamma-Neutron Spectroscopic Personal Radiation Detectors (SPRDs) which utilize advanced search algorithms and can be used for detection and primary radionuclide identification of the radioactive sources even by the non-trained personnel
The SPRDs are designed to detect the slightest amounts of the gamma and neutron radiation emitting materials and evaluate their danger to general public by isotope identification. The PM1703MB Gamma and PM1703GNB Gamma-Neutron models are equipped with a CsI(Tl) (for gamma detection and spectra accumulation) and a LiI(Eu) (for neutron detection) scintillation detectors to alert the user that the radiation levels have exceeded the preset threshold values.
The instrument consists of two separate parts: the PM1703MB/PM1703GNB radiation detector equipped with a Bluetooth module and Polimaster proprietary PoliIdentify software which is used for data processing and radioisotope identification. The external computing device such as smartphone, PDA, laptop, or PC can be used to run the PoliIdentify software. The communication between the radiation detector and the external computing device is done via Bluetooth channel. Such configuration provides high flexibility and a number of benefits to the end-user. For example, the radiation detector part can be used as a conventional standalone personal radiation detector (PRD). This gives an opportunity to upgrade PRD with identification and networking capabilities. In addition, communication via Bluetooth allows user to be at a safe distance from the possible radiation sources while the PM1703MB/GNB is operating. This configuration prevents the instrument operator from unnecessary radiation exposure.
The PM1703MB/GNB SPRD models have the following functions:
Detect only gamma or both gamma and neutron radiation sources (PM1703MB and PM1703GNB respectively);
Search for and locate the gamma or neutron radiation sources including nuclear weapon materials;
Alert the user of the presence of a radiation source through audible, visual and vibrating alarms;
Record and analyze gamma spectra as well as identify radionuclide composition.
In addition to on-site identification the SPRD models have networking capabilities giving the ability to transmit data via internet for off-site analysis and identification.