- Detector: gamma   CsI(Tl), GM tube

- Sensitivity:

+ for 137Сs, no less 85 (s-1)/(μSv/h) (0.85 (s-1)/(μR/h))

+ for 241Am, no less 130 (s-1)/(μSv/h) (1.3 (s-1)/(μR/h))

- Energy range: gamma 0.033 – 3.0 MeV

- Dose Rate: gamma  0.01 μSv/h – 10000 μSv/h (1 μR/h – 1000 mR/h)

Dose:    X

- Accuracy:   ±(20+ К/Н+K2*H)% in measurement range   0.1 μSv/h - 10 Sv/h (10 μR/h-1000 R/h),  where H - dose rate value in mSv/h;   К1 – coefficient 0.0025 mSv/h ;  K2 – coefficient 0.002 (mSv/h)-1

- Response time:   0.25 s

- Radionuclide identification using  Bluetooth communication with   external Pocket PC or smartphone:

+ Special nuclear materials (SNM): X  

+ Medical radionuclides : X  

+ Naturally occurring radioactive  materials (NORM): X  

+ Industrial radionuclides: X  - Standards compliance:  ITRAP/IAEA requirements, ANSI N42.32, ANSI N42.33 (1), ANSI N42.33 (2), IEC 60846, IEC 62401

- Alarm type:   visual, audio, vibration

- Data recording:  1000

- Environmental protection:  IP65

- Drop test on concrete floor: 1.5 m (4.9 ft),  0.7 m (2.3 ft) without cover 

- Power supply:   one AA battery

- Battery life time:   up to 1000 hours

- Operating temperature:  -30°C to 50°C  (-22°F to 122°F)

- Size (without cover):   72 x 32 x 87 mm  (2 7/8 x 1 ¼ x 3 3/8)

- Weight: (without cover)  185 g (6.52 oz);  (with cover) 220 g (7.76 oz)

- Low battery warning:  LCD

- Overload indication:   gamma OL

- PC Communication:  IRDA

 

PM1703MO-1 Product brochure

 

 PM1703MO-2 instruments combine features of both Personal Radiation Detector (PRD) and Dosimeter in the one housing. Each instruments is equipped with two detection modules: their highly sensitive CsI(Tl) scintillation detector allows for searching of the radioactive and nuclear materials and together with small-sized GM tube detector allows for measuring dose rate of gamma radiation in the wide energy range.

The PM1703MO-1 and PM1703MO-2 models offer the highest performance of this type instruments which are currently available on the market. They meet requirements of applicable sections of ITRAP/IAEA, IEC 60846, IEC 62401, ANSI N42.32 and ANSI N42.33 standards. 
The PM1703MO family instruments combine functionality of both Personal Radiation Detector and Dosimeter in the one package. The highly sensitive CsI(Tl) based detector ensures prompt gamma radiation detection and source location and together with GM tube detector enables precise dose rate measurement. 
PM1703MO-2
This modification fulfills requirements of the International Atomic Energy Agency (IAEA) and is widely used for radiation security needs at the international events.
 