Electronics Enclosure: NEMA4X (IP 66) polycarbonate with clear, shatterproof cover

Accuracy: ±0.25% of range or 2 mm (0.08 in); whichever is greater

Display Large: 19 mm (0.75 in) high, 4-digit LCD

Calibration: Selectable Level or Range mode. Enter min. and max. distance in centimeters or inches.

Programming: Built-in 2- button keypad with menu selection. Calibration parameters are permanent when stored, even through a power interruption.

Power Input: 100-130 V AC 50/60 Hz, 5 W maximum

Outputs Isolated: 4-20mA, 1000 ohm load maximum

Signal Relay: 1 Relay, rated 120-240 V AC or 24 V DC, 1 A, programmable for level alarm, echo loss alarm, pump control, or temperature alarm

Temperature compensation: Temperature probe inside the level sensor for high accuracy in changing temperatures

Operating Temperature (Electronics): -25 °C to 60 °C (-13 °F to 140 °F )

Approximate Shipping Weight: 2.7 kg (6 lbs)