Sensors

Types: Combustibles

Technology: Infrared

Detection Method: Diffusion

Min. Detectable Change: ± 1 %LEL

Repeatability: ± 2 % of reading

Accuracy:

- ± 3 % LEL, 0 to 50% LEL

- ± 5 % LEL, 51 to 100% LEL

Response Time (Rise):

- T50 ≤ 5 seconds

- T90 ≤ 10 seconds

Oxygen Requirement: None


Electrical

Power: 18-32 Vdc, measured at detector

5 Watts max

Termination Resistance: < 500 Ω @ 24 VDC

Outputs: 3-wire, 4–20 mA


User Interface

Controls: Zero

Interface: 4 mA level and activator


Environmental

Temperature: -40° to 158°F (-40° to 70°C)

Humidity: 0-99 % RH, non-condensing


Enclosure

Material: 316 Stainless Steel

Ingress: IP54

Weight: 5 lbs (2.3 kg)