Sundy SDTGA6000 Thermogravimetric Analyzer (RT~1000℃, 4kW, 0.5~5g)

お問い合わせ
安全なチェックアウト
高品質な対応
簡単な交換・返品
配送対応可能

Test Index: Moisture, Ash, Volatile Matter and LOI

Continuous Test in Batches: Yes

Standards: ISO 17246, ISO 18123/18122/18134, ISO 11722, ISO 1171, ISO 562, ASTM D3173/D3174/D3175/D7582, GB/T 30732, GB/T 212

Precision: 0.02% RSD

Furnace: Dual furnaces, one for moisture and ash, one for volatile matter

Furnace Temperature: Room temperature~1000℃

Temperature Control Precision: ±2℃

Temperature Resolution: 0.1℃

Reproducibility: Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%); Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%)

Cooling Time Required for Batches of Test: No

Furnace Cooling (forced air/N2): 950 to 500°C <30 min

Balance Resolution: 0.0001g

Sample Introduction and Taking: Automatic

Max. Samples: 19 samples + 1 blank sample position (Moisture & Ash); 25 samples + 1 blank sample position (Volatile matter)

Quantity of Sample / Test Time: Full indexes for 19 samples <120 min (Quick method)

Sample Weight: 0.5 up to 5g

Max. Power: 4kW for moisture/ash testing; 2.5kW for volatile matter testing

Interface: RS232

Furnace Heating: Resistance Wound

Temperature Calibration: Standard thermocouple

Temp. Control Precision: ±2℃ (moisture), ±5℃ (ash, volatile matter)

Gas Flow Rate: GB: Moisture: Nitrogen, 30~60 times/h; Ash: Air 60~120 times/h; ASTM: Moisture: Nitrogen or Air 2~4 (Furnace Volume/min); Volatile matter: Nitrogen 2~4 (Furnace Volume/min)

Power Requirement: AC 220V (±10%), 50/60Hz

Gas Requirement: Nitrogen/Oxygen/Compressed Air

Gas Pressure: Air 5 to 6 bar (75 to 90 psi)

Minimum Gas Purity: Air/Nitrogen/Oxygen 99.5%; dry, oil-free

Sample Weighing: Under normal temperature

Test Temperature: Moisture 105℃, Ash 815℃, Volatile matter 920℃~950℃ (Can be customized)

Humidity: <80%

Dimensions: Moisture & Ash Analyzer: 550x590x530mm; Volatile Matter Analyzer: 550x650x815mm

Weight: Moisture & Ash Analyzer: 70kg; Volatile Matter Analyzer: 95kg

Operational Control: Windows®-based software on external PC / Windows7 / WindowsXP

Advance Calculation: Yes

Analysis Report: Yes

Statistics Report: Yes

System Monitor: Yes

SDTGA6000 can be used to determine the moisture, ash and volatile matter as well as calculation of fixed carbon and calorific value in coal, coke, calcined petrol coke and other solid biomass fuel.

Dual Furnaces, stable performance, accurate test result.

19 samples+1 blank sample for moisture & ash; 25 samples+1 blank sample for volatile matter