The highlights are on the 3-phase starter

2025年01月22日 09時42分50秒

In electric motor control and protection systems, the 3-phase starter is considered an extremely important and useful device. Thanks to its stable operation, this device helps start and stop the engine safely, supporting the optimization of the operating process. But what exactly is a 3-phase starter, and what makes it the preferred choice in industrial applications? Please refer to EMIN in the article below!

What is 3-phase starting? 

3-phase starter (3-phase contactor) is a familiar device in industrial electrical systems. Its main function is to control the current in a 3-phase power system using the magnetic field principle. When power is applied to the coil, the created magnetic field attracts the contacts, effectively closing or shutting off the current. 

Notable characteristics of 3-phase starters  

3-phase starting brings many practical benefits, meeting requirements in industrial environments:  

- Stable performance: Built to withstand high loads, the device operates durably for a long time, suitable for many harsh conditions.  

- Ensure safety: Thanks to protection systems such as thermal relay or overload protection, this device minimizes the risk of incidents, protecting both the motor and the electrical system.  

- High quality materials: The product is made from heat-resistant and abrasion-resistant materials, helping to prolong life even during continuous operation.  

- Convenient installation: Neat design and modular structure make installation and maintenance easier.

Technical specifications of 3-phase starter 

Choosing a 3-phase starter is not simply about buying any electrical device, but requires a detailed understanding of the technical specifications. This is the decisive factor in the ability to meet user needs and ensure efficiency when operating in practice.

- Rated voltage (Ue): This is the maximum voltage level at which the device can operate stably. Depending on the specific application, products usually support voltages from 220V to 600V, suitable for a variety of industrial electrical systems.

- Rated current (Ie): The load capacity of the magnetic starter is expressed through this parameter. With ranges from 9A to 800A, you can easily find the right device for your capacity and operating requirements.  

- Starting current tolerance (Ith): This is the maximum current that the magnetic starter can withstand when starting to activate the motor. This parameter is usually higher than the rated current, ensuring the system operates safely when the load suddenly increases.  

- Number of contacts: The main contacts (usually 3) are responsible for transmitting the main current, while the auxiliary contacts (NO and NC) assist in auxiliary functions such as signaling or remote control .

- Control capacity: Indicates the device's motor control ability, usually calculated in kW.

Related articles: Explain the cause of starting from no suction, what is the solution?

Some popular 3-phase starters today

Currently, on the market there are many types of 3-phase starters designed to meet a variety of industrial and civil needs. Refer to the 3 products below to help you choose the right one for your electrical system:

1. Contactor 3P LS MC-32a (32A, 2NO + 2NC)

This product belongs to LS contactor line with load capacity of 32A, contact configuration includes 2NO and 2NC. This is the optimal choice for systems that require flexibility in controlling power and control circuits, ensuring high durability and stable operation.

2. Contactor Schneider LC1D32M7, 32A, AC3 - 15KW/400V, 1NO + 1NC

Schneider is always highly appreciated for its quality and performance. Model LC1D32M7 can withstand 32A current, rated capacity reaches 15KW at 400V voltage, suitable for systems with small and medium motor loads. The 1NO + 1NC configuration helps ensure flexibility in circuit design.

3. Contactor Siemens 3RT10 34-1AP04, 32A, AC3 - 15KW/400V

Siemens 3RT10 34-1AP04 stands out with its ability to operate stably in industrial environments. With a rated current of 32A and a capacity of 15KW at a voltage of 400V, this product is suitable for systems requiring high reliability. Siemens is also known for its advanced technology that helps increase operating efficiency and equipment longevity.

関連ニュース

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026年11月14日 11時35分16秒

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026年11月14日 10時28分19秒

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026年11月13日 17時23分39秒

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026年11月13日 16時11分22秒

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026年11月13日 15時07分40秒

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room