For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

The Latest Series of Industrial Acoustic Imaging Cameras from Fluke

2024年10月16日 15時57分21秒

The latest line of acoustic imagers from Fluke offers a more intuitive solution for detecting air leaks and mechanical problems. Models ii915, ii905, and ii500 easily identify problems by "seeing" the sound. Thanks to modern technology, the inspection process becomes faster and obtains more relative results, saving time and repair costs.

Fluke ii915 – Specializes in Detecting Compressed Air and Vacuum Leaks

The Fluke ii915 is intended for detecting compressed air and vacuum leaks in industrial environments. With more than 100 ultra-sensitive microphones, this device can operate effectively even in noisy environments where conventional methods find it difficult to detect leaks. 

Fluke ii915

The special feature of ii915 is the ability to display the source of leaks on the screen with visual images, helping you not only detect but also determine the exact location of the problem, helping to reduce inspection time and at the same time Optimize energy efficiency for the plant, minimize compressed air loss and ensure operating processes are always highly efficient. If you are having problems with energy loss in your compressed air system, the Fluke ii915 will definitely be the right choice for you to handle your work tasks.

Fluke ii905 – Remote Local Discharge Detection

When it comes to safety testing of high-voltage electrical systems, the Fluke ii905 is definitely a must-have. Specially designed for remote corona and arc discharge detection

Fluke ii905

Rapid partial discharge detection can prevent equipment damage and ensure the safety of substations and power lines, minimizing risky situations that could lead to downtime or failure. big. With remote detection capabilities, the Fluke ii905 allows you to inspect without getting too close to the equipment, minimizing operator safety risks.

Fluke ii500 – Versatile Device, Comprehensive Solution

If you are looking for a comprehensive solution for both gas leak detection and electrical problems, the Fluke ii500 is the best choice. This device combines both of the above features in a single device, bringing convenience and high efficiency to industrial equipment maintenance activities. 

Fluke ii500

The Fluke ii500 is quite easy to use, not only that, it can also store and analyze images and videos to help you monitor and report problems in detail. This makes maintenance easier, thereby minimizing downtime and optimizing production processes. Suitable for manufacturing plants, especially those that need flexibility in testing and maintaining many different systems.

Practical applications:

Manufacturing Industry & Manufacturing Plants

In manufacturing environments, problems such as compressed air leaks often lead to significant energy waste. Fluke ii915 can solve this problem. Factories often face the problem of energy consumption from compressed air systems that are not properly maintained, causing significant losses in operating costs. With the ability to detect even in noisy environments, the ii915 ensures quick inspections, helping to optimize energy efficiency and minimize downtime for maintenance.

Electrical technology and transformer stations

The Fluke ii905 is especially useful for testing substations, high voltage power lines and power distribution systems. Partial discharge phenomena such as corona or arcing can cause serious problems in the safety and durability of electrical equipment in general. Instead of waiting until a major incident occurs, using ii905 to detect electrical discharges early helps minimize the risk of fire, explosion, equipment damage and prolongs system life. Thanks to remote detection capabilities, technicians do not need to come into direct contact with high-voltage electrical equipment, thereby minimizing safety risks.

HVAC System Maintenance (Heating, Ventilation and Air Conditioning)

In HVAC systems, problems with air leaks or mechanical damage can affect performance and operating costs. The Fluke ii500 can help detect these problems early, thereby minimizing energy loss and extending the life of the system. Early leak detection helps ensure optimal system operation, especially in large commercial buildings or manufacturing environments where HVAC systems play a critical role in maintaining temperature and air quality. gas.

Why Choose an Acoustic Camera Instead of Traditional Methods

Detecting leaks or mechanical problems with acoustic cameras is Fluke's breakthrough innovation in industrial inspection. Compared to traditional methods, "seeing" the sound allows you to identify problems more quickly, minimizing manual inspection time. Fluke II-Series devices make accurate decisions on the spot, thanks to Wi-Fi connectivity and data synchronization with the Fluke Connect platform. From there, sharing data with colleagues or storing it for later reference also becomes easier.

[MINI GAME] FLUKE LAUNCHES NEW PRODUCT - FLUKE LAUNCHES NEW PRODUCT, SHARE NOW TO RECEIVE GIFTS INSTANTLY

To thank customers for their support recently, EMIN&Fluke is having a small minigame for 10 lucky people to have the opportunity to immediately receive cool COOLMATE t-shirts!

How to participate:

Step 1: LIKE this post and EMIN VietNam fanpage

Step 2: SHARE the article in public mode

Step 3: COMMENT with the hashtag #AcousticImagerEMINxFLUKE to participate in Lucky Draw and have a chance to receive a cool COOLMATE t-shirt from us

Event time: From October 18, 2024 to December 24, 2024.

The winning list will be announced on December 25, 2024 in the comments section of this article.

Note: Only 10 lucky people will be randomly selected and announced on December 25, 2024!

Hurry and join now to have the opportunity to receive gifts and discover the most advanced solutions from Fluke!

関連ニュース

DC, Pulsed DC, or RF: Selecting a Plasma Source Based on Material and Process
2026年11月23日 16時55分48秒

In sputtering, positive ions (typically Argon) are accelerated toward a target to bombard and dislodge material. A stable ion current can only be maintained if electric charge does not accumulate on the target surface. The simulation below illustrates this principle qualitatively: the blue trace follows the waveform, while the amber-colored bar represents the level of charge accumulated on the target surface

Errors in Measuring Rebar Diameter within Concrete
2026年11月23日 13時50分41秒

In the quality assessment of reinforced concrete structures using non-destructive testing (NDT) methods, determining the diameter (d) of reinforcing bars directly on a completed structural element often results in significantly greater margins of error compared to measuring the thickness of the concrete cover. If the identified diameter deviates by one or two standard size increments (for example, if a D16 bar is misidentified as a D20 or D12), the entire analysis—including the calculation of load-bearing capacity and the verification of the structural design—loses its reliability.

Assessment and Retrofitting of Reinforced Concrete Structures After Fire Exposure in Accordance with TCVN 14104:2025
2026年11月23日 11時48分42秒

In accordance with the principles for the preservation and post-fire structural assessment stipulated in TCVN 14104:2025, the inspection entity must accurately quantify the extent of cross-sectional degradation in heat-exposed concrete, the presence of subsurface delamination, and the condition of the internal steel reinforcement before developing a strengthening plan.

Hướng dẫn đo nghiệm thu chiều dày lớp bê tông bảo vệ đúng chuẩn TCVN 9356:2012 & Luật Xây dựng 2025
2026年11月21日 10時00分27秒

Để kết quả đo đạt độ tin cậy pháp lý khi làm hồ sơ hoàn công và nghiệm thu với tư vấn giám sát, kỹ sư hiện trường và thí nghiệm viên phòng LAS-XD cần làm chủ quy trình vận hành máy đo chiều dày lớp bê tông bảo vệ, kiểm soát các yếu tố gây nhiễu từ trường và xử lý số liệu đúng quy chuẩn.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス