HT Instrument Electrical Safety Tester for Photovoltaic Systems

2020年12月25日 14時54分10秒

Lắp đặt hệ thống pin mặt trời trên mái nhà liệu có an toàn, hay sẽ tiềm ẩn nguy cơ hỏa hoạn? Hệ thống pin mặt trời có được nối đất đúng cách, hay sự cố lắp đặt sẽ khiến công đầu tư thành công cốc? Liệu người dùng có thể yên giấc mỗi đêm hay sẽ trằn trọc trong lo âu? Có lẽ hầu hết các chủ sở hữu hệ thống pin mặt đều có những mối quan ngại như vậy.

Is my rooftop installation safe, or would it ignite a fire and burn my house? Is my ground installation properly done, or will a fire destroy my investment? Can I sleep loudly or should I worry? Probably most of the owners of PV systems have these doubts.


Solar energy is electric power, and as any electric power, it can be unsafe. A primary cause of solar PV fires is electrical arcing occurring anytime there is a compromise of the electrical system's wiring or connections. The risk for arcs to occur increases over time. This can be attributed to the normal “wear and tear” that a solar PV system is subjected to, making system maintenance a priority. There are many factors that contribute to this condition:

- Corroded cables and connections (cables rubbing against vegetation or roof, birds/rats/insects, saltiness);

- Loose wiring;

- Improper cable support;

- Etc.

IEC/EN 62446 requires the installation to be tested and certified by qualified solar installers. Only professional licensed solar installers using the right measuring instruments can grant the PV installation to be fully complying with the safety guidelines, so safe.
At the beginning of the PV era, the array output voltage used to be up to 600V DC. This benchmark was replaced by 1,000V DC about a decade ago. Now it is surpassed by the new standard 1,500V DC. Voltage increases to higher values, such as 2,000V DC, are unlikely due to the significant cost to develop products specifically designed for high-voltage use. In fact, the IEC considers 1,500V as the low-voltage limit.
1,500V DC systems are the present and the future
HT is proud and honored to introduce PV-ISOTEST is the first and only solar installation tester specifically designed to test the safety of PV installations up to 1,500V. According to IEC/EN 62446, PV-ISOTEST measures the insulation resistance of the whole installation at once by generating up to 1,500V DC, and by withstanding the voltage generated by the installation under test, regardless of its dimension and power generated. This means no need for external devices such as expensive DC-rated switches, the safety of the user while carrying out measurements, no need to section combiner boxes to perform the test string by string, so lots of time saved.


PV-ISOTEST also measures polarization index (PI) and dielectric absorption ratio (DAR) to assess the quality of the insulation. PI and DAR are particularly important when measuring the insulation of long cables in operation for many years. In fact, the insulation resistance value may change over the years due to electrical and mechanical stresses, creating an increase in leakage currents. PI is a ratio of the megohms after 10 minutes divided by the megohms after 1 minute, DAR is the ratio of the megohms at 1 minute divided by the megohms at 30  seconds. High values of PI and DAR mean good or even excellent insulation conditions.
To cut troubleshooting time, PV-ISOTEST is provided with an innovative Ground Fault Locator function, indicating the user which module has a poor insulation to the ground across the string tested. This allows the user to immediately identify the poorly insulated module for further replacement.
PV-ISOTEST also measures the continuity of the protective/equipotential conductor, as required by IEC/EN 62446.
These features make PV-ISOTEST the first and only solar installation tester able to test the safety of PV installations up to 1,500V. PV-ISOTEST beats the (unexisting) competition, another must have made by HT for every professional PV installer.
More information about PV-ISOTEST is available here
Several video tutorials are available on YouTube


関連ニュース

DC, Pulsed DC, or RF: Selecting a Plasma Source Based on Material and Process
2026年11月23日 16時55分48秒

In sputtering, positive ions (typically Argon) are accelerated toward a target to bombard and dislodge material. A stable ion current can only be maintained if electric charge does not accumulate on the target surface. The simulation below illustrates this principle qualitatively: the blue trace follows the waveform, while the amber-colored bar represents the level of charge accumulated on the target surface

Errors in Measuring Rebar Diameter within Concrete
2026年11月23日 13時50分41秒

In the quality assessment of reinforced concrete structures using non-destructive testing (NDT) methods, determining the diameter (d) of reinforcing bars directly on a completed structural element often results in significantly greater margins of error compared to measuring the thickness of the concrete cover. If the identified diameter deviates by one or two standard size increments (for example, if a D16 bar is misidentified as a D20 or D12), the entire analysis—including the calculation of load-bearing capacity and the verification of the structural design—loses its reliability.

Assessment and Retrofitting of Reinforced Concrete Structures After Fire Exposure in Accordance with TCVN 14104:2025
2026年11月23日 11時48分42秒

In accordance with the principles for the preservation and post-fire structural assessment stipulated in TCVN 14104:2025, the inspection entity must accurately quantify the extent of cross-sectional degradation in heat-exposed concrete, the presence of subsurface delamination, and the condition of the internal steel reinforcement before developing a strengthening plan.

Hướng dẫn đo nghiệm thu chiều dày lớp bê tông bảo vệ đúng chuẩn TCVN 9356:2012 & Luật Xây dựng 2025
2026年11月21日 10時00分27秒

Để kết quả đo đạt độ tin cậy pháp lý khi làm hồ sơ hoàn công và nghiệm thu với tư vấn giám sát, kỹ sư hiện trường và thí nghiệm viên phòng LAS-XD cần làm chủ quy trình vận hành máy đo chiều dày lớp bê tông bảo vệ, kiểm soát các yếu tố gây nhiễu từ trường và xử lý số liệu đúng quy chuẩn.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス