For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Unveil the Serial Buses Design - Debug & Troubleshoot Webinar

2020年04月28日 16時41分32秒

Webinar organized by Tektronix, on 9:00 am on 13/5/2020. Please register to attend

Serial bus systems are literally everywhere in our society today. Traditionally, parallel buses are widely used for communicating between the devices in micro-controller and DSP-based designs. Today, however, more and more of the building blocks used in design are replacing these wide parallel buses with serial buses due to less power consumption, differential signaling for better noise immunity and fewer pins and therefore, require less board space.


While serial buses provide a number of advantages, they also pose some significant challenges to a designer due simply to the fact that information is being transmitted in a serial fashion rather than parallel. The difficulty lies in extracting information about the protocol itself and in determining the interactions between devices from a long serial stream of data.


Join our webinar to understand the common challenges for serial bus designers and learn how you can overcome them.


関連ニュース

Choosing Communication Interfaces for Test Equipment
2026年08月10日 15時39分24秒

A practical guide to selecting RS232, GPIB, LAN, USB, or Wi-Fi for test equipment based on connection range, networking needs, computer compatibility, and instrument control requirements.

Comparing Shore A and Shore D Hardness: Two Common Hardness Scales Today
2026年08月10日 14時16分08秒

Both Shore A and Shore D are used to measure material hardness, but each scale is suited to a different group of materials. Soft rubber, silicone, or elastic gaskets are typically tested using Shore A, whereas hard plastics, engineering plastics, and materials with low deformation are better suited to Shore D

What causes equipment to restart automatically in the factory, and how can the fault be identified?
2026年08月10日 11時17分47秒

Equipment restarts in a factory setting can be attributed to voltage sags, momentary power outages, electrical noise, overheating, or hardware faults. For incidents that last only a few power cycles, a power quality analyzer can capture voltage, current, and waveform data at the exact moment of the reset, thereby helping engineers determine whether the power supply is the cause

Why Measured Amplitude Is Lower Than the Real Value
2026年08月10日 09時28分50秒

An oscilloscope can display a lower amplitude than the true signal when its bandwidth is not high enough. This article explains bandwidth, the 5x rule, and rise time in practical terms.