For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

VD 550 – A Powerful Flow Measurement Solution for Industrial Compressed Air Systems

2026年07月01日 16時12分46秒

CS Instruments has introduced the upgraded version of the VD 550 compressed air flow meter with a ¾” threaded connection, designed for measurement applications in high-humidity compressed air environments and demanding operating conditions.

VD 550 Compressed Air Flow Meter Expands Measurement Capability Directly After the Air Compressor

In industrial compressed air systems, the measurement point immediately downstream of the compressor is often the most challenging area to control due to high flow rates, elevated temperatures, and continuous condensate formation. As a result, many facilities either install additional treatment equipment before the measuring point or accept unstable measurement data.

The VD 550 compressed air flow meter with a ¾” threaded connection was developed to directly address this challenge. The device enables reliable measurement of humid compressed air and technical gases directly after the compressor, even when no water separator is installed upstream of the measuring point.

In addition to the new design, the accessory package includes a ¾” threaded fitting and a drilling tool for creating a 20 mm measuring port, enabling fast installation for both new systems and retrofit projects.

High-Sensitivity Compressed Air Flow Sensor for Low Flow Ranges

One of the key advantages of the VD 550 is its ability to measure flow velocities starting from 2 m/s, allowing accurate monitoring even when the system operates under low-load conditions or experiences frequent demand fluctuations.

This feature makes the instrument particularly suitable for variable-speed air compressors, where airflow does not remain constant throughout the operating cycle.

According to the manufacturer’s technical specifications, the sensor utilizes differential pressure measurement combined with temperature and pressure compensation to maintain measurement accuracy across various operating conditions.

From a single measuring point, users can simultaneously monitor: Flow rate, Total consumption, Temperature, Pressure

As a result, the VD 550 is not only as a flow measurement device but also as a valuable tool for compressed air consumption monitoring and energy management.

VD 550 Designed for High Flow Rates, Harsh Environments, and Large Pipe Sizes

As industrial compressed air systems continue to expand in capacity, sensors are increasingly required to support larger pipe diameters and withstand demanding operating conditions.

The VD 550 gas flow meter offers several key advantages:

Measurement in Temperatures up to 180°C

Suitable for installation near compressors and in high-temperature industrial gas applications.

Compatible with Pipe Sizes DN20–DN600

Supports flexible deployment from small production lines to centralized compressed air distribution systems.

IP67 Die-Cast Aluminum Housing for Industrial Environments

Impact-resistant construction suitable for field installation and environments with dust or high humidity.

Supports Multiple Industrial Communication Standards

The VD 550 can be seamlessly integrated into centralized control systems, SCADA, PLC, and energy management platforms through multiple communication interfaces:

  • 4–20 mA

  • Pulse Output

  • RS485 (Modbus RTU)

  • Ethernet (Modbus TCP / PoE)

  • HART

  • IO-Link

  • M-Bus

  • Profibus DP / Profinet via Gateway

Its capability to operate directly with humid compressed air, combined with a design optimized for large pipelines and flexible connectivity, makes the CS Instruments VD 550 compressed air flow meter well suited for the digitalization of operational data in modern manufacturing facilities.

関連ニュース

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026年11月14日 11時35分16秒

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026年11月14日 10時28分19秒

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026年11月13日 17時23分39秒

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026年11月13日 16時11分22秒

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026年11月13日 15時07分40秒

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス