For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

VD 550 – A Powerful Flow Measurement Solution for Industrial Compressed Air Systems

2026年07月01日 16時12分46秒

CS Instruments has introduced the upgraded version of the VD 550 compressed air flow meter with a ¾” threaded connection, designed for measurement applications in high-humidity compressed air environments and demanding operating conditions.

VD 550 Compressed Air Flow Meter Expands Measurement Capability Directly After the Air Compressor

In industrial compressed air systems, the measurement point immediately downstream of the compressor is often the most challenging area to control due to high flow rates, elevated temperatures, and continuous condensate formation. As a result, many facilities either install additional treatment equipment before the measuring point or accept unstable measurement data.

The VD 550 compressed air flow meter with a ¾” threaded connection was developed to directly address this challenge. The device enables reliable measurement of humid compressed air and technical gases directly after the compressor, even when no water separator is installed upstream of the measuring point.

In addition to the new design, the accessory package includes a ¾” threaded fitting and a drilling tool for creating a 20 mm measuring port, enabling fast installation for both new systems and retrofit projects.

High-Sensitivity Compressed Air Flow Sensor for Low Flow Ranges

One of the key advantages of the VD 550 is its ability to measure flow velocities starting from 2 m/s, allowing accurate monitoring even when the system operates under low-load conditions or experiences frequent demand fluctuations.

This feature makes the instrument particularly suitable for variable-speed air compressors, where airflow does not remain constant throughout the operating cycle.

According to the manufacturer’s technical specifications, the sensor utilizes differential pressure measurement combined with temperature and pressure compensation to maintain measurement accuracy across various operating conditions.

From a single measuring point, users can simultaneously monitor: Flow rate, Total consumption, Temperature, Pressure

As a result, the VD 550 is not only as a flow measurement device but also as a valuable tool for compressed air consumption monitoring and energy management.

VD 550 Designed for High Flow Rates, Harsh Environments, and Large Pipe Sizes

As industrial compressed air systems continue to expand in capacity, sensors are increasingly required to support larger pipe diameters and withstand demanding operating conditions.

The VD 550 gas flow meter offers several key advantages:

Measurement in Temperatures up to 180°C

Suitable for installation near compressors and in high-temperature industrial gas applications.

Compatible with Pipe Sizes DN20–DN600

Supports flexible deployment from small production lines to centralized compressed air distribution systems.

IP67 Die-Cast Aluminum Housing for Industrial Environments

Impact-resistant construction suitable for field installation and environments with dust or high humidity.

Supports Multiple Industrial Communication Standards

The VD 550 can be seamlessly integrated into centralized control systems, SCADA, PLC, and energy management platforms through multiple communication interfaces:

  • 4–20 mA

  • Pulse Output

  • RS485 (Modbus RTU)

  • Ethernet (Modbus TCP / PoE)

  • HART

  • IO-Link

  • M-Bus

  • Profibus DP / Profinet via Gateway

Its capability to operate directly with humid compressed air, combined with a design optimized for large pipelines and flexible connectivity, makes the CS Instruments VD 550 compressed air flow meter well suited for the digitalization of operational data in modern manufacturing facilities.

関連ニュース

Reactive Power Compensation Capacitors Bulging or Exploding Before Their Design Lifespan
2026年09月17日 16時10分45秒

The capacitor labels indicated a 10-year lifespan, yet after just two years of service, the casings began to bulge; some even exploded, accompanied by a popping sound and a burnt odor that permeated the electrical room. The maintenance team would install replacements, only for the exact same issue to recur a few months later. This cycle repeated multiple times before anyone finally questioned whether the failures were due to the capacitors reaching the end of their service life or because they were being subjected to conditions beyond their original design specifications.

Overheated Neutral Wire and Neutral Current Exceeding Phase Current: What Are the Causes?
2026年09月17日 15時44分48秒

According to balanced three-phase circuit theory, the neutral current should ideally be zero or negligible compared to the phase current. Yet, technicians frequently discover during inspections at electrical panels that the neutral wire is extremely hot, with measured neutral currents sometimes even exceeding the current in individual phase wires. This is neither a rare occurrence nor a measurement instrument error; rather, it indicates that the system's loads are non-linear, generating harmonics that traditional conductor sizing methods fail to account for

Fetal Sex Determination in Cows During Pregnancy
2026年09月17日 10時31分45秒

Ultrasound-based fetal sex determination in cows can support herd planning, selection decisions, and reproductive strategy when performed at the appropriate stage of pregnancy.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス