Veer Electronics VPA-60080 3 Phase Precision Power Analyzer (TRMS 2400V, 400A)
KEY FEATURES
TRMS Voltage 600V/1200V/1400V Phase, 1050V/2100V/2400V Line
TRMS Current 80A / 160A/ 300A/ 400A Direct
500 Test Data Storage Inbuilt (1000 Optional)
USB, RS-232 / RS-485 interface & Free Software
20 X 4 Jumbo LCD & Ultra Glow Red LED Display
High Speed Measurement in 0.25 Sec (Optional)
Torque, RPM, %Slip, Eff. Measurement (Motor Version)
Flow, Head, RPM, %Slip Measurement (Pump Version)
Auto Over Voltage Shutdown Facility (Optional)
Inbuilt Surge Protection in Selective Models
Double Fuse Protection
2 Wattmeter, 3 Wattmeter Measurement Facility
2 in 1 Rack Mountable & Table Top Model
User Friendly Operation with embossed Key Pad
Tamper Proof Calibration & Long term stability
NABL certified in EQDC & ERDA
CT-PT Ratio Setting Facility (Optional)
SCOPE OF MEASUREMENT
TRMS, Mean, Rectified and Peak, Crest Factor, Form Factor of Voltage and Current.
Active Power(P), Apparent Power(S) and Reactive Power (Q), Power Factor, Frequency accurately.
Torque, RPM, %Slip, Output Power, Direct Efficiency of Motor (Motor Version)
Flow, Pressure, Suction, %Slip, RPM of Pump (Pump Version).
GENERAL SPECIFICATION
Warm up time: 30 minutes
Operating Temperature: 5 °C to 50 °C
Operating Humidity: 20% to 80% RH (no condensation)
Storage Temperature: 0 °C to 55 °C
Power supply: 160V - 290V @ 50Hz Or 100V - 140V @ 60 Hz
Power consumption: 30VA Max.
Dimension (Wx Dx H): 376 x 320 x 145 mm**
Panel Cut Out Size: 332 × 133 mm without Feet**
Weight: 5.5 kg approx.**
Input terminal type:
Voltage: Banana socket (wire fit type)
Current: large binding Post (1/4" or 6/16" copper stud with insulated nut)
MEASUREMENT FUNCTION
Parameter
Accuracy (within 1 year after Calibration*)
Conditions: -
Temperature: 25 °C+ 5 °C
Humidity: 30 - 75% RH
Input: Sine wave
Power factor : 1.0
Display digits : 5 / 6 digits
Sample Avg:10 Sample
*Normal test & input condition
Voltage / Current / Active power
Frequency Range: 45 Hz to 65 HZ
Accuracy: ±(0.1% Reading + 0.1% Range)
Peak / Mean = Above x 2
Additional PF effect on Active Power measurement: At 50Hz 0.035 ° or Time delay errors 2.5 uS
Effective Input range: 10-100% of Voltage, 1-100% current range rating
Display updating value: 0.25 to 10 seconds in selected models
Frequency Measurement:
For Input >= 3% of VI 45 to 65 Hz
Accuracy ± 0.05%
Frequency between VI Input & Neutral Terminal
SPECIFICATION FOR EXTRA CHANNELS
Parameters: Flow, Pressure
Measuring Range: 4 - 20 mA
Accuracy / Remark: ± 0.20 % on FSD
Parameters: Torque
Measuring Range: Depends on Sensor
Accuracy / Remark: ± 0.20% on FSD
Parameters: RPM
Measuring Range: Depends on Sensor
Accuracy / Remark: ± 0.1% on FSD