For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

Webinar: Spectrum View - A New Approach to Frequency Domain Analysis on Oscilloscopes

2020年06月02日 08時48分34秒

Spectrum View is a new way of performing spectrum analysis on an oscilloscope. The ADC in the oscilloscope sends high-speed digitized data down two paths

Spectrum View is a new way of performing spectrum analysis on an oscilloscope. The ADC in the oscilloscope sends high-speed digitized data down two paths. One path leads to hardware decimators which determine the rate at which time domain samples are stored. The second path leads to digital down-converters also implemented in hardware. This approach enables independent control of the time domain and frequency domain acquisitions, allowing optimization of both waveform and spectrum views of a given signal. It also makes much more efficient use of the long but finite record length available in these instruments.


Date: June 10, 2020

Time: 8:00 am (TH time), 9:00 am (SG time)


Insert alt text here


In this webinar, we will show and explain how Spectrum View operates and how it differs from traditional oscilloscope FFT functions. Join us today!




関連ニュース

Comparing Shore A and Shore D Hardness: Two Common Hardness Scales Today
2026年08月10日 14時16分08秒

Both Shore A and Shore D are used to measure material hardness, but each scale is suited to a different group of materials. Soft rubber, silicone, or elastic gaskets are typically tested using Shore A, whereas hard plastics, engineering plastics, and materials with low deformation are better suited to Shore D

What causes equipment to restart automatically in the factory, and how can the fault be identified?
2026年08月10日 11時17分47秒

Equipment restarts in a factory setting can be attributed to voltage sags, momentary power outages, electrical noise, overheating, or hardware faults. For incidents that last only a few power cycles, a power quality analyzer can capture voltage, current, and waveform data at the exact moment of the reset, thereby helping engineers determine whether the power supply is the cause

Why Measured Amplitude Is Lower Than the Real Value
2026年08月10日 09時28分50秒

An oscilloscope can display a lower amplitude than the true signal when its bandwidth is not high enough. This article explains bandwidth, the 5x rule, and rise time in practical terms.

Why Measured Amplitude Can Be Lower Than the Real Value
2026年08月10日 09時27分59秒

An oscilloscope can display a lower amplitude than expected when its bandwidth is too limited for the signal being measured. This article explains the relationship between bandwidth, rise time, and measurement accuracy.

お得な情報を受け取る

数量割引、まとめ買い価格の更新、新製品情報をメールでお届けします。

登録することで、当社の利用規約およびプライバシーポリシーに同意したものとみなされます。

クイックサポート

認定専門家へ直接アクセス