HORIBA 8007-10C カドミウムイオン電極
生産者: HORIBA Model: 8007-10C 起源: Japan 品物を保証します: 3 Month - 要件クオート
- 連絡先
Measurement Range:
0.1 to 11,240 mg/L Cd2+
(10-6 to 10-1 mol/L) Cd2+
Temperature Range: 0 - 50 ºC
pH Range: 11 mg/L (10-4 mol/L) Cd2+pH 3 to 8
Applicable temperature range: 0 to 50℃
Response time (90%): Within 10 seconds
Applicable reference electrode: 2060A, 2565A
Selection coefficient:
Cu2+、Hg2+Ag+ = Not acceptable
Pb2+ = 0.1 Fe3+ = 1
Cr3+、Fe2+ = 100
Ni2+ = 1,000
• The response time is the time which is required to reach 90% response when the ion concentration is gradually changed from 10-4 mol/L to 10-2 mol/L with the solution stirred.
Exception:
*1: 90% response when ion concentration is changed to 10-6 mol/L ∼ 10-2 mol/L
*2: 95% response when ion concentration is changed to 10-3 mol/L ∼ 10-1 mol/L
*3: 95% response when ion concentration is changed to 10-4 mol/L ∼ 10-2 mol/L
*4: 95% response when ion concentration is changed to 10-4 mol/L ∼ 10-1 mol/L
• The selection coefficient is a ratio of the limit concentration of coexisting ions (mol/L) to the ion concentration to be measured (mol/L); The value of 1000 means that the coexisting ions can be permitted up to 1000 times the ion measured and ''not acceptable'' means that chemical change occurs in the solid response membrane.