Charging Function: With constant current and constant voltage charging function

Discharge Function: With constant current and current limiting discharge function

Charge and Discharge Interface: Fully supports same-port charging/discharging and separate charging/discharging of battery packs, compatible with 2-wire (P+ P-) and 3-wire (P+ P- C-) configurations

USB Interface: Equipped with USB interface

Application: Used with barcode scanner to collect battery pack ID numbers for convenient data query after battery aging

Safety Protection: Anti-reverse connection protection function

Voltage Protection: Upper and lower voltage limit protection setting

Safe Discharge Current Protection: Maximum current 10A


Charging Requirements:

Charging Voltage: 0–70V, continuously adjustable, accuracy ±1mV (high precision dedicated)

Charging Current: 0–5000mA, continuously adjustable, accuracy ±1mA (high precision dedicated)


Discharge Requirements:

Discharge Voltage: 0–70V, accuracy ±1mV (high precision dedicated)

Discharge Current: 0–10A, accuracy ±1mA (high precision dedicated)

Discharge Capacity Error: 1‰ (high precision dedicated)

Features

1. In the network mode, it is connected automatically, without manual connection.

2. Use MYSQL database to save data to ensure that data will not be lost, and provide measurement data review function.

3. A small number of instruments can communicate with PC software through the serial port.

4. Multiple instruments can use the network to communicate with PC software, which reduces the computer interface. Only one network port is needed to control all instruments, ensuring the real-time and complete communication data.

5. The instrument number is displayed through LED lights, and the position of the corresponding instrument can be queried intuitively. The number can be modified by software, which reflects the flexibility of the instrument.

6. In addition to the P+ and P- interfaces, the instrument also provides CH+ and CH-, which can test special finished batteries and charge and discharge them on one instrument.

7. The battery can be charged as long as the battery is in the test range, avoiding the problem that the charger can only charge a specific type of battery.