인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결
Input Voltage:
200/208, 400, or 480 VAC (all ±10%)
3, 4 wire, 50 to 60 Hz, no neutral required
Efficiency: >87%
Power Factor: >0.90 for loads > 2 kW
Output Voltage: Low-Z and standard-Z options (please refer to individual specification information)
Output Polarities: Floating default with positive and negative capability
Output Ripple Voltage: The component of output ripple voltage related to input line frequency is <2% RMS
Output Power Repeatability: 0.1% from 10% to 100% of rated power (from run to run at a constant set point)
Remote Panel or Host Port: ±1% of full-rated output
User Port: 1% or ±0.2% of full-rated output, whichever is greater
Line Regulation: No accuracy derating for line voltages within the specified input voltage range
Load Regulation: No accuracy derating for impedances within the specified output impedance range
Temperature Coefficient: <0.005%/°C variation in the regulated output parameter over 20° to 40°C (68° to 104°F) ambient temperature range
Product Line (Overall): Specification accuracy is Cpk <1.5
I/O Control
Analog Interface Options:
37-pin isolated (to 500 VRMS), 0 to 10 VDC analog, 0/24 VDC digital
37-pin, 0 to 10 VDC analog, 0/15 VDC digital
37-pin, 0 to 5 VDC analog, 0/15 VDC digital
Serial Communication Options:
RS-232, RS-422, RS-485 (selectable baud rates up to 115.2 k):
• AE Bus protocol
• ASCII protocol (MDX and emulation)
Profibus (selectable baud rates of 1.5 or 12 MB); AE Bus protocol
DeviceNetTM option available