For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Advanced Energy IN 5 plus Non-Metal Applications Pyrometer (-32 ~ 900°C)

ModelIN 5 plus
보증12개월
문의하기
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

- Temperature Ranges: -32 ~ 900°C (-25.6 ~ 1652°F) (MB 9)
- IR Detector: Thermopile
- Data Handling: Digital
- Spectral Range: 8 ~ 14 μm
- Emissivity ε: 0.2 ~ 1.0 adjustable
- Measurement Uncertainty Tamb (ε =1, t90 = 1 s):
T = -32 ~ 0°C: 1.5°C (Tamb = 15 ~ 30°C); 2°C (Tamb = 0 ~ 15°C or 30 ~ 63°C)
T = 0 ~ 300 °C: 0.6% of reading in °C or 1°C (Tamb = 15 ~ 30°C); 1% of reading in °C or 1.5°C (Tamb = 0 ~ 15°C or 30 ~ 63°C)
T = 300 ~ 900°C: 1% of reading in °C (Tamb = 15 ~ 30°C); 1.3 % of reading in °C (Tamb = 0 ~ 15°C or 30 ~ 63°C)
- Repeatability (ε =1, t90 = 1 s): 0.3% of reading in °C or 0.6°C
- Noise Equivalent Temperature Difference (NETD) (ε =1, tamb = 23°C ):
@ t90 = 80 ms: 0.2°C (@ 23°C measuring temperature)
@ t90 = 1 s: 0.05°C (@ 23°C measuring temperature)
- Optics: Zinc-Sulfide (ZnS)
3 fixed optics:
100 mm, 300 mm, and 800 mm
- Sighting: Laser targeting light (max power level < 1 mW, λ = 630 ~ 680 nm, CDRH class II)
Electrical:
- Power Supply: 24 VDC (18 ~ 30 V); nominal, ripple must be less than 0.5 V
- Power Consumption: Max 70 mA
- Load: Max 500 Ω @ 24 V (max. 200 Ω @ 18 V)
Environmental
- Protection Class: IP 65 (DIN 40050)
- Ambient Temperature: 0 ~ 63°C (32 ~ 145.4°F)
- Storage Temperature: -20 ~ 70°C (-4 ~ 158°F)
- Relative Humidity: Non-condensating conditions
- Weight: Approx 410 g (~14.47 oz)
- Housing: Stainless steel
- CE Label: According to EU directives about electromagnetical immunity
Interface and Communication:
- Analog Output: 0 ~ 20 mA or 4 ~ 20 mA (linear), adjustable
- Exposure Time t90: 0.08 s
- Scope of Delivery: Instrument with selected optic, works certificate, PC measurement and evaluation software InfraWin.

Datasheet

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결