인증된 전문가에게 직접 연결
인증된 전문가에게 직접 연결

Specifications:
BK 1655A
Voltage Adjustment Range: 0-150 VAC with input at 120 VAC
Output Isolation Leakage less than: 0.1 mA (25 0C, 50% RH)
Current Ranges: 0-3 A
Maximum Current: (Isolated) 3A continuous, 4A intermittent (0-130V)
Peak Current (inrush): 30A max. (inrush limited to one cycle at 30A)
Voltage/Current Sensing Sine wave average, calibrated in RMS
Meter Scale: 0-240VAC / 0-480VAC (voltage set at 120)
Leakage: 0-5000 uA
(expanded in 100-500 uA portion, compressed to 5 mA full scale)
Metering 4 1/2 multicolor scales, overrange protected
Typical Meter Accuracy +-5% of full scale (volts and current)
+-5% at 500 uA (leakage)
Soldering Iron Temp. Control 70 - 99% of power line (100W max.)
AC Input 120 VAC ±10%, 60 Hz*
Dimensions (HxWxD) 10.5x5.7x12" (267x145x305 mm)
Weight 22 lbs. (10 kg)