Digital Communications I/O: RS485 (select applicable analog I/O)
Mechanical Connection(Body size 0 & 1 only): 1/4” VCR w/filter
Valve Type: Normally Closed (≤1500 psi)
O-ring material : Viton
Analog Communications I/O: 4 - 20mA / 4 - 20mA
Revision Level: REVB
Gas or Range: 3ccm-50lpm
Performance
Pressure Accuracy (Including linearity and Hysteresis): ±0.25% of Transducer F.S., F.S. > 300 psia, ±0.12% of Transducer F.S., F.S. ≤ 300 psia
Control Range: 20:1 Typical - Application specific
Repeatability & Reproducibility: 0.20% S.P.
Linearity: Included in accuracy
Response Time (Settling Time within ± 2% F.S. for 0 - 100% command step): System dependent
Zero Stability: <+0.001% F.S. per 30 days
Temperature Coefficient: <+0.1% F.S. per °C
Attitude Sensitivity: The accuracy of the Pressure Sensor is not attitude dependent
Ratings
Operating Temperature Range: (-14) - 65°C (7 - 149°F)³
Transducer Pressure Ratings:
15 psia / 1.03 bara for <15 psia F.S.
15 psia / 1.03 barg for <15 psig F.S.
100 psia / 6.9 bara for <100 psia F.S.
100 psia / 6.9 bara for 15 - 100 psig F.S.
300 psia / 20.7 bara for 100 - 300 psia F.S.
300 psig / 20.7 barg for 100 - 300 psig F.S.
3000 psia / 206.9 bara for 300 - 3000 psia F.S.
4500 psia / 310.3 bara for 3000 - 4500 psia F.S
Leak Integrity (External): 1 x 10⁻⁹ atm. cc/sec He