For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0

How to calculate and choose the right hydraulic pump for the system

2025년 07월 16일 14시 28분 38초

Hydraulic pumps operate based on the rotary motion provided by an electric motor or diesel engine. When operating, it has the task of sucking liquid such as oil or lubricant and pushing it continuously through the system, ensuring the entire circuit operates smoothly. Therefore, this device plays a key role in any hydraulic system.

Calculating and selecting the right hydraulic pump is not easy, especially for those who do not have much experience. If you are wondering how to determine the parameters to choose the right pump, please refer to the article below. Specific instructions will help you more easily calculate and choose the pump that meets the technical requirements.

Overview of hydraulic pumps in the system

Hydraulic pump, also known in English as Hydraulic Pump, is one of the core components of the hydraulic transmission system, along with devices such as valves, cylinders, oil tanks or filters. The main task of the pump is to create a pressurized oil flow, bringing oil from the tank to the actuators so that the system can operate continuously. Normally, the pump will be installed near the tank to ensure the most effective oil suction and discharge. After being sucked up, the oil will follow the pipe through the control valves, to the one-way or two-way cylinders depending on the design. When the oil returns to the tank, the pump continues the next operating cycle, creating a closed loop.

Because of its central role, pump selection cannot be arbitrary. During design or maintenance, technicians need to calculate and select hydraulic pumps based on parameters suitable for the system. If selected incorrectly, the pump can work beyond its capacity, causing overheating, reduced efficiency or rapid damage.

See more: Configuration and operating principles of hydraulic pumps

Instructions on how to calculate and choose hydraulic pumps

In a hydraulic system, the pump is the device that determines whether or not it can generate enough force or torque for the actuators to operate effectively. If you choose the wrong type of pump or do not calculate carefully, the system may end up consuming unnecessary energy or not having enough capacity to operate.

The first step in calculating the choice of a hydraulic pump is to determine the type of pump you need to use. For example, when you need a large flow but not too high pressure, you can consider using a vane pump or a piston pump. In the case where the system requires high pressure but not much flow, a gear pump will be a worthy choice.

Next, you should also clarify whether you will use an electric or manual pump depending on the specific purpose and working environment. 

Next is the most important step: calculating parameters such as capacity, working pressure and oil flow that the pump needs to provide. These data can be determined by technical formulas and compared with the parameters from the manufacturer.

How to calculate hydraulic pump flow

Flow is understood as the volume of oil that the pump can push in a certain period of time. The common units of flow are cubic meters per hour or liters per minute.

On each pump, you can see the specific flow index - this is the amount of oil the pump produces in one revolution. The common unit is cc per revolution.

To calculate the actual flow of the pump, you can use the following formula:

Q = q × n

Trong đó:

Q is the pump flow rate, usually in liters per minute or cubic meters per minute

q is the specific flow rate, in cc per revolution

n is the number of revolutions per minute of the pump drive motor

Hydraulic pump pressure

After determining the flow rate, the next factor you need to consider when calculating the selection of a hydraulic pump is the pump pressure. This is a parameter that represents the ability to generate force or torque for the hydraulic cylinders and motors in the system. To calculate the pressure required for the pump, you can use the formula:

P = F / S

In which:

F is the force that the system needs to generate to push the load, the unit is Newton

S is the cross-sectional area of the piston rod, the unit is square meter

P is the pressure generated, the original unit is Newton per square meter. However, in practice, people often convert to more common units such as bar or psi. Specifically, 1 bar is equivalent to 100,000 Newtons per square meter.

How to calculate pump capacity

Based on the two available parameters of flow and pressure, you can continue to determine the required capacity of the pump according to the formula below:

N = P × Q / 612

In which:

P is pressure, unit bar

Q is flow, unit liters per minute

N is the required capacity of the pump, unit kilowatt

An important note in the process of calculating and selecting a hydraulic pump is that the pump should not be operated at the limit continuously. To ensure durability and stable performance, you should choose a pump pressure higher than the actual calculated pressure. For high pressure systems, add about 10 percent. For systems requiring low or medium pressure, the reserve level should be between 20 and 30 percent. This helps avoid pressure drops or performance reduction after a long period of operation.

관련 뉴스

Which products are tested using a -40°C to +150°C thermal shock chamber?
2026년 07월 22일 14시 45분 25초

Automotive circuit boards, sensors, modules, and plastic components can all experience issues after repeated transitions between cold and hot environments. A thermal shock chamber operating from -40°C to +150°C enables the replication of these temperature fluctuations under controlled testing conditions.

Does thermal shock cause damage to electronic components?
2026년 07월 22일 10시 40분 49초

An electronic component may operate stably under constant temperature conditions yet fail after repeated rapid transitions between hot and cold. The issue typically stems not from a specific temperature level, but rather from the rate of temperature change and the number of hot-cold cycles

The rigorous standards behind a multi-million-dollar MRI suite
2026년 07월 21일 14시 54분 01초

An MRI system may be correctly installed and fully connected to the power supply, yet still encounter issues if the surrounding environment fails to meet technical specifications. Electromagnetic interference, RF shielding, power quality, grounding, temperature, humidity, and particulate levels are all factors that may require assessment, depending on the facility's design and the manufacturer's requirements.

Sinusoidal and Random Vibration: A Test Setup Guide for Industrial Engineers
2026년 07월 21일 10시 30분 38초

During the operation of industrial machinery or the transportation of goods, persistent mechanical vibrations inevitably occur; these are a primary cause of material fatigue, loosened connections, and cracking in printed circuit boards (PCBs). To ensure product integrity before delivery to customers, R&D and QA/QC engineers must simulate these dynamic forces using vibration test systems.

Capacities of laboratory centrifuge tubes
2026년 07월 20일 13시 55분 40초

Tubes with capacities of 0.2 ml, 1.5 ml, 15 ml, or 50 ml are commonly found in laboratories, yet each type is associated with specific sample categories and equipment configurations. DNA and RNA samples typically require small-volume microtubes; blood and cell samples often utilize 5 ml or 15 ml tubes; while large-volume processing workflows may require tubes of 50 ml, 100 ml, or greater capacity