Chauvin Arnoux C.A 1621 온도 교정기 TK

ModelC.A 1621
P/NP01654621
원산지China
보증1 년
부가세 별도
31,740,485 VND
부가세 포함
34,279,724 VND
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

- Input/Output range: - 10 mV to 100 mV
- Resolution : 0.01 mV
- Accuracy: ± 0.025 % + 2 counts
Function
- Type J
+ Range: - 200 to + 1,200 °C  
+ Resolution: 0.1°C
+ Accuracy: ± (0.3°C + 10 μV) 
+ Reference junction error: ± 0.3°C
- Type K 
+ Range: - 200 to + 1,370 °C  
+ Resolution: 0.1°C 
+ Accuracy: ± (0.3°C + 10 μV) 
+ Reference junction error: ± 0.3°C
- Type T 
+ Range: - 200 to + 400   
+ Resolution: 0.1°C 
+ Accuracy: ± (0.3°C + 10 μV) 
+ Reference junction error: ± 0.3°C
- Type E
+ Range: - 200 to + 950   
+ Resolution: 0.1°C 
+ Accuracy: ± (0.3°C + 10 μV) 
+ Reference junction error: ± 0.3°C
- Type R
+ Range: - 20 to + 1,750 °C  
+ Resolution: 1°C
+ Accuracy: ± (1 °C + 10 μV)
+ Reference junction error: ± 0.3°C
- Type S
+ Range: - 20 to + 1,750 °C  
+ Resolution: 1°C
+ Accuracy: ± (1 °C + 10 μV)
+ Reference junction error: ± 0.3°C
- Type B
+ Range: +600 to + 1,800 °C  
+ Resolution: 1°C
+ Accuracy: ± (1 °C + 10 μV)
+ Reference junction error: ± 0.3°C
- Type N
+ Range: - 250 to + 1,300 °C  
+ Resolution: 0.1°C 
+ Accuracy: ± (0.3°C + 10 μV) 
+ Reference junction error: ± 0.3°C
- General specification
+ Power supply : 6 x 1.5 V
+ Dimension : 205 x 97 x 45 mm/ 472 g
+ Mains power supply: Input: 100 V – 240 VAC, 50–60 Hz 1.8 A ; Output: 12 VDC, 2 A MAX

Delivered with 2 thermocouple adapters, 6 AAA 1.5 V batteries, 1 operating manual in 5 languages and 1 carrying bag
Accessory: Mains power supply P01103057

datasheet
user guider

Calibrators offer two major functions: simulation and measurement.
SIMULATION: The first function involves simulating a signal or generating a quantity with precisely-defined values. These quantities are applied upstream of the measurement chain.
MEASUREMENT: The second function, involving the measurement of the signal. If there isa panel meter at the end of the chain,you can compare its value with the one indicated by the calibrator. If there is no panel meter, the simulated input value is compared with the signal measured by the calibrator
-The whole range of calibrators
(C.A 1621, C.A 1623 and C.A 1631) is designed to accurately measure, generate or simulate all the low-level signals encountered in industry.
Because they are simple to use, they are ideal for on-site work. Due to the wide variety of sensors recognized, these  instruments are suitable for all your applications.
Powered by batteries, these calibrators are stand-alone instruments offering a long battery life. When connected to the mains, they can be used continuously for as long as necessary!

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결